5.11 Pulsed Transient Operation Example
This example selects CV pulsed transient operation, selects the bus as the trigger source, and programs a pulse width of 1 millisecond.
1 "INPUT OFF" Turns off the load‘s input
2 "MODE CV" Selects the CV mode
3 "TRIG:SOUR BUS" Selects the bus as the trigger source
4 "VOLT: LLEV 0.5" Sets the transient low level to 0.5 V
5 "VOLT:HIGH 1" Sets the transient high level to 1 V
6"TRAN:HTIM 1ms" Sets transient high level time to 1 ms
7 "TRAN:RTIM 10us" Sets the time for transient rising edge to 10 μs
8 "TRAN:FTIM 10us" Sets the time for transient falling edge to 10 μs
9 "TRAN:MODE PULSE " Selects the pulsed transient operation
10 "TRAN ON" Activates the transient operation
11 "INPUT ON" Turns on the load` s input
12 "*TRG" *TRG command generates a 1 millisecond high-level pulse at the load‘s input