2.10 Measurement Function
The electronic load has measurement system with high resolution. The input current level and voltage level can be measured in real
time. The input power level and resistance level can be computed with the input voltage level and current level. Each measured value
can be checked through LCD display or via remote command (MEASure).
2.11 Saving and Recalling
The electronic load is provided with an EEPROM memory, which can save various parameters, such as modes, input status, current,
voltage, resistance, transient settings, limits, etc.
SPL Series electronic load can save 10 groups of parameters.
All parameters relevant to saving and recalling operation are listed in List 2-1.
The 10 groups of parameters stored in Location 0~9 can be saved and recalled by pressing
key + key and key +
key, or via the remote command (*SAV < NRl > and *RCL < NRl >).
The parameter saved in Location 0 will be recalled automatically every time the load is turned on.
List 2-1
* indicates it only can be programmed in the remote control.
2.12 Reading Remote Programming Errors
The Err indicator will be turned on when remote programming errors occur. The error codes are shown as followings:
Remote programming errors can be checked by pressing key after pressing key on the front panel. The remote command
(SYSTem:ERRor?) can read back the error codes and error messages when it is in remote control.
Function Effect Default
using the
example of
SPL 400-40
Input Input status Off
Mode Operation mode CCH
Current level Immediate current level 0 A
Current rise rate Current rise rate 4 A/μs
Current fall rate Current fall rate 4 A/μs
Current Hlevel Transient current high level 0 A
Current Llevel Transient current low level 0 A
*Current protection level Current limit 40 A
*Current protection delay Current protection delay 60 s
*Current protection State Enable/disable current protection off
Voltage level Immediate voltage level 80 V
CV current limit Current limit in CV mode 40 A
Voltage Hlevel Transient high voltage level 80 V
Voltage Llevel Transient low voltage level 80 V
Resistance level Immediate resistance level 2000 Ω
Resistance Hlevel Transient high voltage level 2000 Ω
Resistance Llevel Transient low voltage level 2000 Ω
Power level Immediate power level 0 W
Transient operation Transient test off
Transient mode Transient mode continuous
Transient Htime Time for transient high level 0 ms
Transient Ltime Time for transient low level 0 ms
Transient Rtime Time for transient rising edge 0.01 ms
Transient Ftime Time for transient falling edge 0.01 ms
Trigger Function Trigger function selection Tran
Trigger source * Trigger source external
Battery Mode Battery discharge operation off
Battery mini voltage Battery minimum termination voltage 0 V
Batterieentladestrom Battery discharge current 0 A
Voltage on Von point for the load 0 V
Voltage on Latch Latch the Von point Off
-lxx Command errors
-2xx Execution errors
-3xx Device-specific errors
-4xx Query errors