The Eload Registration Records show the parameters of all registered load. To add a new load, click the
button.
Fig.2-17 Add new load window
Enter the Eload Name, Address and the maximum value of current, power, resistance, then press “OK” to
confirm. Note: the Eload ID is assigned by the software.
The Parameter Explanation
Parameter Explanation
Range
Eload ID ID
Eload Name
Name
ASCII
Eload Address Address 0-254
Max Current Maximum Current 0-30A
Max Power Maximum Power 0-150W /300W
Max Resistance Maximum Resistance
0-500Ω
To delete a registered load, select the load from the Eload Registration Records, then click the button.
To modify a load’s parameters, select the load from the Eload Registration Records, then click
the
button.
To query a load, click the button, then enter the load name you want to query.
Attention: after the Add, Modify, Delete operation, the program must restart so that the modifications may take
effect. The following dialog box will be shown, click “Yes” to close the program, then restart the program from
the Start menu.