User manual

SSL LOAD KONSTANTER SERIES 32 EL
16 GMC-I Messtechnik GmbH
Programming procedure is shown below:
1Select Program Set from menu operation, the LCD will display:
Constant Curr
Constant Power
Constant Resis
Use the UP and DOWN keys or rotary knob to select
Constant Current mode, and press “OK” to confirm.
2LCD will display:
Step Number=*
New=
Input the program length “3” and press “OK” to confirm.
3 LCD will display:
Step1 Set=0.00
New=
Input the current value “1”A, then press “OK” to confirm.
4 LCD will display:
Step Time=1s
New=
Input the time value “2”s, then press “OK” to confirm.
5 LCD will display:
Step2 Set=0.00
New=
Input the current value “2”A, then press “OK” to confirm.
6 LCD will display:
Step Time=1s
New=
Input the time value “5”s, then press “OK” to confirm.
7 LCD will display:
Step2 Set=0.00
New=
Input the current value “3”A, then press “OK” to confirm
8 LCD will display:
Step Time=1s
New=
Input the time value “10”s, then press “OK” to confirm.