User manual

SSL ELECTRONIC LOAD SERIES 32 EL
GMC-I Messtechnik GmbH
27
Set Current: Press “I set”, input the current value (0~30A), press “ENTER” to confirm.
Set Power: Press “P set”, input the power value (3710A: 0~150W¸3711A: 0~300W), press “ENTER” to confirm.
Set Resistance: Press “R set”, input the resistance value (0~500), press “ENTER” to confirm.
I Max, P Max, R Max: show the max value of each parameter.
2.7 The Amp, Power, Resistance, Voltage Meter
The Amp, Power, Resistance, Voltage Meter show the setting and read back value of current, power, resistance
and voltage.
Fig.2-9 The Amp, Power, Resistance, Voltage Meter
2.8 Dynamic Curve
These curve show the dynamic states of voltage and current.
Fig.2-10 The Voltage Curve Fig.2-11 The Current
Curve
You may drag your mouse on the curve to zoom in/out.