User manual

GMC-I Messtechnik GmbH 31
FSEt - memory location-specific voltage or current function
Function
This parameter determines which function is to be performed
during the transition to this memory location..
This command has been available as from firmware version
03.004.
Setting parameters
nF SEQUENCE values USET, ISET, TSET without addi-
tional function
rU Voltage ramp from the previous to the new voltage
setpoint value, duration TSET and/or TDEF
rI Current ramp from the previous to the new current
setpoint value, duration TSET and/or TDEF
Settings
Procedure for selecting FSEt: see chapter 4.7 - Settings.
! The display of the SEq function shows the value for FSEt and
the associated alphanumerical parameter.
Set the parameter with key <> or <>
The parameter is accepted upon acknowledging with the
<ENTER> key.
After selecting the value, jump to the next or the previous
sequence function by pressing the <FUNCTION> key, or by
simultaneously pressing the <FUNCTION> key and the <> key
or the <> key.
tSEt – Memory Location-Specific Dwell Time
Functions
Special dwell time (see also Figure 4.7.3):
For the voltage-current value pair at a specific memory
location within a SEQUENCE
Setting Range
00.00 s The tdEF value is used.
00.01 s to 99.99 s Maximum resolution: 0.01 s
99.99 s Assignment of the specified time to
several consecutive SEQUENCE memory
locations with identical voltage and
current values
The values include rise time and decay time (see also Figure
4.7.3). Edge times are only assured within a limited load
impedance range (see also Technical Data).
Settings (see sequence settings and execution on page 35)
Procedure for selecting tSEt: see also chapter 4.7 - Settings.
! The tSEt display appears in the window for the SEq function,
along with a related numeric parameter [s].
Figure 4.7.3 b Path to tSEt Settings
Set resolution, i.e. the decimal place (cursor position) of the
numeric parameter by repeatedly pressing the <RESOL> key.
Enter dwell time based on the previously entered resolution
value using the <> key or the <> key.
After selecting the value, jump to the next or the previous
sequence function by pressing the <FUNCTION> key, or by
simultaneously pressing the <FUNCTION> key and the <> key
or the <> key.
The last selected and displayed value for the numeric dwell
time parameter is used as a default setting.
Select the text parameter
from an options loop
ENTER
RESOL
Cursor position
Resolution of
numeric parameter
*
From the SEq function group
CE/LOCAL
FUNCTION SAVE
RCL
Uset/Iset FUNCTION
MENU
SAVE
MENU
RCL
MENU
FUNCTION
MENU
Activate
the setting
Abort
without change