-224 Illegal parameter value
A discrete parameter was received which was not a valid choice for the command. You may have used an invalid parameter
choice.
Example: DISP:STAT ABC (ABC is not a valid choice).
-350 Too many errors
The error queue is full because more than 20 errors have occurred. No additional errors are stored until you remove errors
from the queue. The error queue is cleared when power has been off, or after a *CLS (clear status) command has been
executed.
-410 Query INTERRUPTED
A command was received which sends data to the output buffer, but the output buffer contained data from a previous
command (the previous data is not overwritten). The output buffer is cleared when power has been off, or after a *RST (reset)
command has been executed.
-420 Query UNTERMINATED
The power supply was addressed to talk (i.e., to send data over the interface) but a command has not been received which
sends data to the output buffer. For example, you may have executed an APPLy command (which does not generate data)
and then attempted an ENTER statement to read data from the remote interface.
-430 Query DEADLOCKED
A command was received which generates too much data to fit in the output buffer and the input buffer is also full. Command
execution continues but all data is lost.
501 Isolator UART framing error
502 Isolator UART overrun error
511 RS232 framing error
512 RS232 overrun error
513 RS232 parity error
521 Input buffer overflow
522 Output buffer overflow
7.3 Self-Test Errors
Code Explanation
601 Front panel does not respond
603 System ADC test failed
607 Rundown too noisy
630 Fan test failed
631 System DAC test failed
632 Hardware test failed
633 Temperature Sensor disconnect