User manual

GOSSEN-METRAWATT 29
FOO!<t6><t7> Instruction: Define bottom lines 6 and 7. They are only output in the statistics
printout.
Each of these bottom lines may contain a maximum of 24 characters. The
bottom lines are checked for validity after each initial start (checksum) and are
eventually deleted.
How to output the contents of the function test memory
FKT? The function test memory of the PSI module is output.
If the memory is empty, Not-Acknowledge is prompted.
The PSI module sequentially sends all records of the memory.
A record contains a complete function test of the SECUTEST tester, e.g.:
<Pmax;L;Imax;W;t>$CS<CR>
If a function test was not made, merely $24 is shown (24 = CHECKSUM $).
If several records are stored, after the first record a ';' is sent as delimiter
in place of <CR>.
The last record in a response ends with $CS<CR>.