User manual
GOSSEN-METRAWATT 29
FOO!<t6><t7> Instruction: Define bottom lines 6 and 7. They are only output in the statistics 
printout.
Each of these bottom lines may contain a maximum of 24 characters. The 
bottom lines are checked for validity after each initial start (checksum) and are 
eventually deleted.
How to output the contents of the function test memory
FKT? The function test memory of the PSI module is output. 
If the memory is empty, Not-Acknowledge is prompted.
The PSI module sequentially sends all records of the memory.
A record contains a complete function test of the SECUTEST tester, e.g.:
<Pmax;L;Imax;W;t>$CS<CR>
If a function test was not made, merely $24 is shown (24 = CHECKSUM $).
If several records are stored, after the first record a ';' is sent as delimiter 
in place of <CR>.
The last record in a response ends with $CS<CR>.










