Data Sheet

SECUTEST BASE / PRO and SECULIFE ST BASE(25)
Test Instruments for
Measuring
Electrical Safety of Devices
12 GMC-I Messtechnik GmbH
SECUTEST BASE/PRO, SECULIFE ST BASE(25) (List of Order Features)
1)
10 A/25 A-R
PE
mesasurements are only possible with line voltages of 115 V/
230 V and line frequencies of 50 Hz/60 Hz.
Sample order SECUTEST BASE10 with English user interface:
M7050 AA02 C01 G01 (highlighted features (in this case boldface,
with gray background in the table ) belong to the fixed basic
equipment of SECUTEST BASE10, the other features can be selec-
ted as desired)
AA02: Device variant SECUTEST BASE10; C01: user interface, keyboard layout and test
sequences in English; G01: R-PE test current for protective conductor measurement:
200 mA and 10 A
Device Variants
SECUTEST BASE
(M7050 AA01 E00
G00 H00 I00 J00
KB00 M00)
SECUTEST BASE10
(M7050 AA02 E00
G01 H00 I00 J00
KB00 M00)
SECUTEST PRO
(M7050 AA03 E01
G01
H01 I01 J00
KB01 M00)
SECULIFE ST BASE
(M7050 A01 AA11
E01 G01
H01 I01 J00
KB01 KC00 M00)
SECULIFE ST BASE 25
(M7050 A01 AA12
E01 G02
H01 I01 J00
KB01 KD01 M00)
Article Number basic instrument M7050
Article number/
Feature AA01 AA02 AA03 AA11 AA12
Connections – plug for mains power supply and test socket is country-specific in each case
Germany with detection of terminals and safety classes B00 –,– –,– –,– –,– –,–
UK B01 –,– –,– –,– –,– –,–
FR/CZ/PL B03 –,– –,– –,– –,– –,–
China B04 –,– –,– –,– –,– –,–
USA B05 –,– –,– –,– –,– –,–
AUS B06 –,– –,– –,– –,– –,–
DK B07 –,– –,– –,– –,– –,–
IT B08 –,– –,– –,– –,– –,–
CH with detection of terminals and safety classes B09 –,– –,– –,– –,– –,–
User interface language (preset language upon delivery, can be subsequently changed to any of the other languages listed below)
German C00 –,– –,– –,– –,– –,–
English C01 –,– –,– –,– –,– –,–
French C02 –,– –,– –,– –,– –,–
Italian C03 –,– –,– –,– –,– –,–
Spanish C04 –,– –,– –,– –,– –,–
Czech C05 –,– –,– –,– –,– –,–
Dutch C06 –,– –,– –,– –,– –,–
Polish C07 –,– –,– –,– –,– –,–
Data entry via touchscreen
without E00
with E01
R-PE test current for protective conductor measurement
200 mA G00
200 mA and 10 A
1)
(not in combination with G02) G01
200 mA and 25 A G02
Connection for 2
nd
test probe
without H00
with H01
DVM function (digital voltmeter) with 2 additional measurement inputs, COM–V
without I00
with I01
Connection for application parts
without J00
with J01
Additional test sequences
without KA00 ✔✔✔✔✔
IEC 60601 KA01 ooooo
Database expansion
without KB00 ✔✔
with (corresponds to Z853R – SECUTEST DB+) KB01 oo✔✔✔
Database Comfort
without KD00
with (corresponds to Z853S – SECUTEST DB COMFORT) KD01 oooo
Bluetooth without M00 ✔✔✔✔✔
with M01 ooooo
DAkkS calibration certificate (language combinations)
D-GB-F P00 –,– –,– –,– –,– –,–
D-GB-PL P01 –,– –,– –,– –,– –,–
D-GB-IT P02 –,– –,– ,– –,– –,–
DAkkS calibration certificate (recalibration) ooooo
Key:
preset, o optional