Instructions

9
METRACELL BT PRO GMC-I Messtechnik GmbH
3.6 Characteristic Values
Measuring
Function
Multimeter /
Connector
Multimeter /
Trickle
Charge /
Discharging /
Charging
Multimeter /
Interval U /
Interval U+I
Multimeter Resistance
Measured
Quantity
V
DC
V
DC
V
DC
V
AC
R
el
+ R
ct
Display
Range
−2450.00 …
+2450.00 mV
−24.5000 …
+24.5000 V
−600.000 …
+600.000 V
−300.000 …
+300.000 V
00.00 …
1000.00 m
Measuring
Range
−2450.00 …
+2450.00 mV
−24.5000 …
+24.5000 V
−600.000 …
+600.000 V
−300.000 …
+300.000 V
00.10 …
1000.00 m
Resolution 0.01 mV 0.1 mV 1 mV 10 mV 0.01 m
Input Imped-
ance / Test
Current
>10M 1.6 M 1.6 M 1.6 M
lp: approx.
2A
Intrinsic
Uncertainty
±(0.05%
rdg. + 10 d)
±(0.05%
rdg. + 10 d)
±(0.05%
rdg.+ 50 d)
±(2.0%
rdg. + 10 d)
1)
1)
Within a frequency range of 45 to 500 Hz.
Note!
Characteristic values for the AC/DC current clamp sensor, the temperature sensor
and the DMA 35 density meter can be found in the respective product documenta-
tion.
±(3.0%
rdg. + 8 d)
S+
Measuring Connections
••
S− ••
P+
P−/
COM
•••••