Condensed Operating Instructions METRACELL BT PRO Portable Battery Tester 3-447-073-03 1/2.20 Read the full operating instructions which are available in PDF format at www.gossenmetrawatt.com.
METRACELL BT PRO GMC-I Messtechnik GmbH Table of Contents 1 Safety Instructions ............................................................................................................. 1 2 Applications ....................................................................................................................... 3 2.1 Intended Use / Use for Intended Purpose .................................................................. 3 2.2 Use for Other than Intended Purpose ............................
METRACELL BT PRO 1 GMC-I Messtechnik GmbH Safety Instructions Observe this documentation, in particular all included safety information, in order to protect yourself and others from injury, and to prevent damage to the instrument. • Carefully and completely read and adhere to these condensed operating instructions, as well as the instrument’s operating instructions. The respective documents can be found at http://www.gossenmetrawatt.com. Retain these documents for future reference.
GMC-I Messtechnik GmbH • • • • • • • • • • • • • • • • METRACELL BT PRO Plugging in the measurement cables and the power pack must not necessitate any undue force. Connect the ground wire before connecting the voltage conducting cable, and disconnect the voltage conducting cable before disconnecting the ground wire. Check measurement cable continuity. Avoid short circuits due to incorrectly connected measurement cables.
METRACELL BT PRO 2 Applications 2.1 Intended Use / Use for Intended Purpose GMC-I Messtechnik GmbH Periodic testing and well-organized maintenance are necessary in order to assure the availability of stationary battery systems. The METRACELL BT PRO is a multifunctional instrument for testing batteries and battery blocks*. It can be used to determine the current status of the battery or battery block, and to pinpoint concealed defects.
METRACELL BT PRO GMC-I Messtechnik GmbH 3 The Instrument 3.1 Scope of Delivery Please check for completeness. 1 METRACELL BT PRO 2 Alligator clips (KY95-3) 4 1.2 V AA batteries 1 Set of multimeter test probes (KS29) 1 Power pack 2 Kelvin probes for 4-wire measurement 1 Rubber holster 1 BT PRO Manager (battery tester management software) 1 Carrying strap 1 Test report / factory calibration certificate 1 Carrying case 1 Condensed operating instructions 3.
METRACELL BT PRO 3.
GMC-I Messtechnik GmbH METRACELL BT PRO Measuring Inputs All measuring inputs refer to ground and reference potential, P/COM input. The measuring inputs are not electrically isolated from each other. The measuring ranges depend on the respective measuring inputs. Measur- Description ing Input S− Input for measuring DC voltage. Measuring range: ±2450.00 mVDC Resolution: 0.01 mV Input impedance: > 10 M Sensing lead to minus pole during resistance measurement.
METRACELL BT PRO GMC-I Messtechnik GmbH Function Keys Key Function “Function” key – Switch on and off – Press briefly: Return to next higher menu level or cancel measurement – Press and hold: End measurement or reactivate Scroll down key “▼” Selection of menu items or digits in downward direction. Scroll up key “▲” Selection of menu items or digits in upward direction.
METRACELL BT PRO GMC-I Messtechnik GmbH 3.5 Technical Data Power Supply Rechargeable NiMH batteries, 4 ea. 1.2 V type AA (recommended: Ansmann maxE 2500 mAh) Input Impedance Measuring input S+: Measuring input S–: Ambient Conditions Operating temperature: +5 ... +40 °C Storage temperature: -20 ... +60 °C Relative humidity max. 75%, no condensation allowed Elevation: max.
METRACELL BT PRO 3.6 GMC-I Messtechnik GmbH Characteristic Values Measuring Function Multimeter / Connector Measured Quantity VDC Multimeter / Trickle Multimeter / Charge / Interval U / Multimeter Discharging / Interval U+I Charging VDC VDC VAC Resistance Rel + Rct Display Range −2450.00 … −24.5000 … −600.000 … +2450.00 mV +24.5000 V +600.000 V −300.000 … 00.00 … +300.000 V 1000.00 m Measuring Range −2450.00 … −24.5000 … −600.000 … +2450.00 mV +24.5000 V +600.000 V −300.000 … 00.
GMC-I Messtechnik GmbH 4 METRACELL BT PRO Initial Startup These condensed operating instructions only explain initial startup of the instrument and basic operating procedures. Please refer to the full operating instructions for a complete description of all functions and settings (available at http://www.gossenmetrawatt.com). Electrical Power Supply 10 Attach the Carrying Strap (optional) 11 Switching the Instrument On 11 Getting Started 12 1. 2. 3. 4. 4.
METRACELL BT PRO GMC-I Messtechnik GmbH Operating time is approximately 10 hours when the batteries are fully charged. A warning is generated when battery voltage drops to below 4.8 V. The battery tester can be operated for approximately one more hour after this warning is generated. 4.2 Attach the Carrying Strap (optional) The battery tester indicates readiness for operation and successful acquisition of measured values by means of an acoustic signal for all measurements and repeat measurements.
GMC-I Messtechnik GmbH METRACELL BT PRO Note! The battery tester can also be switched off by pressing the Function key. The key must be pressed and held for approximately 10 seconds to this end. However, it’s preferable to switch the instrument off using the switch off function. 4.4 Getting Started After switching the instrument on (11), the main menu appears at the display. This is the central menu from which all other hierarchically subordinate menus and functions can be accessed.
METRACELL BT PRO GMC-I Messtechnik GmbH Measurement Description DMA 35 (IrDA) Measurement of acid density and electrolyte temperature within a block. Measurements are performed with the DMA 35 density meter (version 3) from Anton Paar GmbH. Data is transferred from the sensor to the battery tester via infrared (IrDA). DMA 35 (BT) Measurement of acid density and electrolyte temperature within a block. Measurements are performed with the DMA 35 density meter (version 4) from Anton Paar GmbH.
GMC-I Messtechnik GmbH 5 METRACELL BT PRO Product Support If required please contact: GMC-I Messtechnik GmbH Product Support Hotline 6 Phone: +49-911-8602-0 Fax: +49-911-8602-709 E-mail: support@gossenmetrawatt.com Repair and Replacement Parts Service / Calibration Center and Rental Instrument Service If required please contact: GMC-I Service GmbH Service Center Beuthener Str. 41 90471 Nürnberg, Germany Phone: +49 911 817718-0 Fax: +49 911 817718-253 E-mail: service@gossenmetrawatt.
METRACELL BT PRO 7 GMC-I Messtechnik GmbH CE Declaration The battery tester fulfills all requirements of applicable EU directives and national regulations. We confirm this with the CE mark. A factory calibration certificate or test report is included with the battery tester.
GMC-I Messtechnik GmbH 8 METRACELL BT PRO Return and Disposal This instrument is subject to directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) and its German national equivalent implemented as the Waste Electrical and Electronic Equipment Act (ElektroG) on the marketing, return and environmentally sound disposal of electrical and electronic equipment.
GMC-I Messtechnik GmbH METRACELL BT PRO © GMC-I Messtechnik GmbH Edited in Germany • Subject to change without notice / errors excepted • A PDF version is available on the Internet Alle Handelsmarken, eingetragenen Handelsmarken, Logos, Produktbezeichnungen und Firmennamen sind das Eigentum ihrer jeweiligen Besitzer. All trademarks, registered trademarks, logos, product designations and company names are the property of their respective owners.