Data Sheet

Camille Bauer Data sheet U 539 Le – 02.14 3
SINEAX U 539
Transducer for AC voltage
Ambient tests
EN 60 068-2-6: Vibration
Acceleration: ± 2 g
Frequency range: 10 150 … 10 Hz, rate of frequency
sweep:
1 octave/minute
Number of cycles: 10, in each of the three axes
EN 60 068-2-27: Shock
Acceleration: 3 × 50 g
3 shocks each in 6 directions
EN 60 068-2-1/-2/-3: Cold, dry heat, damp heat
IEC 1000-4-2/-3/-4/-5/-6
EN 55 011: Electromagnetic compatibility
Germanischer Lloyd
Type approval certifi cate: No. 12 259-98 HH
Ambient category: C
Vibration: 0.7 g
Specifi cation and ordering information
Description
*Blocking
code
No-go with
blocking code
Article No./
Feature
SINEAX U 539 Order Code 539 - xxxx xxx 539 –
Features, Selection
1. Mechanical design
Housing P8/35 for rail mounting 4
2. Nominal input frequency
50 / 60 Hz 1
3. Measuring range
0 … 100 V A
0 … 250 V B
0 … 500 V C
Non-standard 0 … 50 to 0 … 600 V [V] Z
4. Output signal
0 … 20 mA, R
ext
≤ 750 Ω A 1
4 … 20 mA, R
ext
≤ 750 Ω A 2
4 … 20 mA, 2-wire connection, R
ext
dependent on power supply B 3
Non-standard 0 … 1 to 0 … < 20 [mA]
0.2 … 1 to < (4 … 20)
A9
0 … 10 V, R
ext
≥ 1 kΩ A A
Non-standard 0 … 1.00 to 0 … < 10 [V]
0.2 … 1 to 2 … 10
AZ
5. Power supply
230 V, 50/60 Hz C B 5
24 V DC CBA
24 V DC via output circuit at 2-wire connection C A B
24 … 60 V DC, AC (DC, AC power pack) B C
85 … 230 V DC, AC (DC, AC power pack) B D
6.
Measuring range adjustable
Measuring range end value permanently set (standard) 0
Measuring range can be adjusted approx. ± 10%
Only in combination with DC, AC power pack, feature 5, line C or D!
C1