SDS
Gorilla Heavy Duty Construction Adhesive Ultimate SDS
Page 3 of 8
Safety Data Sheet – Gorilla Heavy Duty Construction Adhesive Ultimate
Date Revised:
Date Issued: 10/15/2018
FOR CHEMICAL EMERGENCY:
During Business Hours: (800) 966-3458 | Outside Business Hours: (800) 420-7186
Version: 1.0
According to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Methods and Material for Containment and Cleaning Up
For Containment: Absorb and/or contain spill with inert material, then place in suitable container.
Methods for Cleaning Up: Dispose of waste safely and in accordance with local, state, federal, national, and international
regulations.
Reference to Other Sections
See heading 8, Exposure Controls and Personal Protection. Concerning disposal elimination after cleaning, see item 13.
SECTION 7: HANDLING AND STORAGE
Precautions for Safe Handling
Hygiene Measures: Handle in accordance with good industrial hygiene and safety procedures. Wash hands and other exposed areas
with mild soap and water before eating, drinking, or smoking and again when leaving work.
Conditions for Safe Storage, Including Any Incompatibilities
Storage Conditions: Keep away from food, drink and animal feeding stuffs. Recommended storage temperature. 10 - 35 °C. Keep
from freezing. Keep container tightly closed and dry. Protect from moisture. Product cures with moisture.
Incompatible Materials: Water.
Specific End Use(s)
Construction Adhesive
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
Control Parameters
For substances listed in section 3 that are not listed here, there are no established Exposure limits from the manufacturer, supplier,
importer, or the appropriate advisory agency including: ACGIH (TLV), NIOSH (REL), OSHA (PEL), Canadian provincial governments, or
the Mexican government.
Titanium Dioxide (13463-67-7)
USA NIOSH
NIOSH (IDLH) (mg/m³)
5000 mg/m³
USA OSHA
OSHA TWA (mg/m³)
15 mg/m³ (total dust)
USA ACGIH
OEL TWA (mg/m³)
10 mg/m³
Mexico
TWA (mg/m³)
TWA: 10 mg/m3
Mexico
STEL: (mg/m³)
STEL: 20 mg/m3
Methyl Alcohol (67-56-1)
USA ACGIH
ACGIH TWA (ppm)
200 ppm
USA ACGIH
ACGIH STEL (ppm)
250 ppm
USA OSHA
OSHA PEL (ppm)
200 ppm
USA OSHA
OSHA PEL TWA (mg/m³)
260 mg/m³
USA NIOSH
IDLH (ppm)
6000 ppm
USA NIOSH
TWA (ppm)
200 ppm
USA NIOSH
TWA (mg/m³)
260 mg/m³
USA NIOSH
STEL (ppm)
250 ppm
USA NIOSH
STEL (mg/m³)
325 mg/m³
Mexico
TWA (ppm)
200 ppm
Mexico
TWA (mg/m³)
260 mg/m³
Mexico
STEL (ppm)
250 ppm
Mexico
Stel (mg/m³)
310 mg/m³
Exposure Controls
Appropriate Engineering Controls: Use with local exhaust ventilation. Ensure adequate ventilation, especially in confined