1
. IDENTIFICATION OF PRODUCT
Product Name: Dries White 2X Faster Gorilla Glue®
Product Type: Polyurethane adhesive
Distributor: The Gorilla Glue Company
4550 Red Bank Expressway
Cincinnati, OH 45227
Tel: (513) 271-3300
Fax: (513) 527-3742
2. HAZARDS IDENTIFICATION
Harmful by inhalation. Irritating to eyes, respiratory system and skin. May cause sensitization by inhalation and skin
contact.
NFPA: Health – 2, Flammability – 1, Reactivity – 1
0=Insignificant 1=Slight 2=Moderate 3=High 4=Extreme
HMIS: Health – 2*, Flammability – 1, Reactivity – 1
0=Minimal 1=Slight 2=Moderate 3=Serious 4=Severe *=Chronic Health Hazard
3. COMPOSITION/INFORMATION ON INGREDIENTS
Chemical name CAS No. % content
Aromatic Polyisocyanate based on MDI 167883-19-4 60 %
Diphenylmethane-diisocyanate (MDI) 26447-40-5 20 %
(Mixed Isomers)
4,4’-Diphenylmethane Diisocyanate (MDI) 101-68-8 20 %
4. FIRST AID MEASURES
Inhalation If aerosol or vapor is inhaled in high concentrations: Move affected individual to fresh air and keep
him warm, let him rest. If there is difficulty in breathing; call a doctor.
Eye contact Flush eyes for at least 10 minutes while holding eyelids open. Contact a doctor.
Skin contact Remove contaminated clothes immediately, and wash skin with a cleanser based on polyethylene
glycol or with plenty of warm water and soap. Consult a doctor in the event of a skin reaction.
Ingestion Product is not intended to be ingested or eaten. If this product is ingested, it could cause gastro-
intestinal blockage. If ingested, it may cause severe irritation of the gastrointestinal tract, and
should be treated symptomatically. Do not induce the patient or animal to vomit. Call a doctor,
ambulance or seek veterinarian assistance immediately.
5. FIRE FIGHTING MEASURES
Upper flammable limit (UFL): Not determined
Lower flammable limit (LFL): Not determined
General fire hazards
Down-wind personnel must be evacuated. Do not reseal contaminated containers; a chemical reaction generating
carbon dioxide gas pressure may occur resulting in rupture of the container. Dense smoke is emitted when
product is burned without sufficient oxygen. When using water spray, boil-over may occur when product
temperature reaches the boiling point of water, and the reaction forming carbon dioxide will accelerate. MDI
vapor and other gases may be generated by thermal decomposition.