SDS
-----Page: 2 of 4-----
DONGGUAN NUOXING ELECTRONIC CO.
,
LTD
Material Safety Data Sheet for Nickel Metal Hydride Batteries(Ni-MH )
Ref.No.:NX2013052101
Section IV - Fire and Explosion Hazard Data
Flash Point (Method Used)
:
N.A Flammable Limits
:
N.A.
LEL
:
N.A UEL
:
N.A
Extinguishing Media
:
Carbon Dioxide, Dry Chemical or Foam extinguishers.
Do not dispose of battery in fire - may explode.
Special Fire Fighting Procedures: N.A.
Do not s hort-circuit battery - may cause burns.
Section
Ⅴ
- Reactivity Data
Stability
:
Stable
Incompatibility (Materials to Avoid):Hazardous Decomposition or Byproducts
Polymerization
:
Will Not Occur
Section VI - Health Hazard Data
◆Swallowing
Do not i nduce vomiting. Seek medical attention immediately.
◆
Eyes
If the contents from an opened battery comes into contact with the eyes, immediately flush
eyes with water continuously for at least 15 minutes. Seek medical attention.
◆
Skin
If the internal cell materials of an opened battery comes into contact with the skin,
immediately flush with water for at least 15minutes.
◆
Inhalation
If potential for exposure to fumes or dusts occurs, remove immediately to fresh air and seek
medical attention.
Health Hazard (Acute and Chronic) / Toxic logical information
◆ In case of electrolyte leakage, skin will be itchy when c ontaminated with electrolyte. In
contact with electrolyte can cause severe irritation and chemical burns.
Section VII – First Aid Measures
First Aid Procedures
:
◆ If electrolyte leakage occurs and makes contact with skin, wash with plenty of water
immediately.
◆
If electrolyte comes into contact with eyes, wash with copious amounts of water for fifteen
(15) minutes, and contact a physician.