Operation Manual
Instructions for Use
6
Placing and Installation
Choosing the Right Place
Place the appliance in a dry and regulariy
ventilated room. Allowed ambient temperature
depends on the model (class) of the appliance
and is stated on the rating plate of the appliance.
If you have amodel with integrated switch for
intensive cooling, consider the instructions in
chapter "Temperature selection".
Never place the appliance near heat emitting
devices (e.g. cooker, radiator, water heater or
similar devices) and do not expose it to direct
sunlight.
The appliance should be positioned at least 3 cm
away from the electric or gas cooker and at least
30 cm away from the oil or coal stove. If this is
not possible, use an appropriate insulation.
Behind the appliance there should be free space
at least 200 cm²
wide and above the appliance
the high kitchen units should be at least 5 cm
away from the appliance in order to assure
adequate ventilation of the condenser unit.
Class Ambient temparature
SN (subnormal) from + 10°C to + 32°C
N (normal) from + 16°C to + 32°C
ST (sub-tropical) from + 18°C to + 38°C
T (tropical) from + 18°C to + 43°C
Placing the Appliance
• Place the appliance firmly on a solid base.
Some appliances have adjustable feet on the
front side; use them to level the appliance.
• Two spacers attached to the appliance must be
fitted onto the upper edge of the condenser,
thus preventing the appliance from being
installed too close to the wall. Spacers are
manufactured for all-purpose function
depending on the distance of the condenser
from the wall. Therefore turn spacers
correspondingly and fix them to the appliance.
Connection to Power Supply
ELECTRICAL CONNECTION
For your safety please read the following
information
Warning: This appliance must be earthed.
The appliance must be connected to a 220-240
volts 50 cycle AC supply by means of a three pin
socket, suitably earthed and should be protected
by a 13 amp fuse in the plug or a15 amp fuse in
the consumer unit.
The appliance is supplied with a moulded 13 amp
3 pin mains plug fitted with a 13amp fuse. Should
the fuse require replacement, it must be replaced
with a fuse rated at 13 amp and approved to
BS1362.
The plug contains a removable fuse cover that
must be refitted when the fuse is replaced. In the
event of the fuse cover being lost or damaged,
the plug must not be used until a replacement
cover has been obtained.
If the moulded mains plug is unsuitable for the
socket outlet in your home or is removed for any
other reason, then the fuse should be removed
and the cut off plug disposed of safely to prevent
the hazard of electric shock.
There is a danger of electric shock if the cut off
plug is inserted into any 13 amp socket outlet.
How to wire a 13 amp plug.