Operation Manual

142396
13
Fault: Cause/Remedy
The appliance does not operate
after connection to the mains:
Check if there is power in the socket and if the appliance is
switched on.
Cooling system operates
continuously without intermittent
stoppages:
Ambient temperature too high.
Frequent opening of the door, (open too long).
Door not closed properly (particle between door gasket,
sagged door, check gasket sealing, etc...).
Excessive quantity of fresh food inserted at once.
• Refrigerator sensor (A) is crammed with fresh food. Free
the sensor and allow air to circulate around it.
Check air circulation for suf cient cooling of the
compressor, and clean the condenser.
Excessive ice formation at the rear
interior wall of the refrigerator:
• Frequent opening of the door, door open too long.
• Placing hot food in the refrigerator.
• Food is touching the rear interior panel.
• Bad door sealing; clean or replace the gasket if dirty or
damaged.
Water dripping from the appliance: • Drain outlet is clogged, drain water drips past the
collection groove.
• Clean the clogged outlet using plastic straw.
• Please thaw out larger ice deposits manually (see chapter
Defrosting).
Bulb replacement:
• Before replacing the light bulb, disconnect the appliance
form the power supply. Using the screwdriver remove the
cover, replace the bulb with a new one (E 14, max. same
voltage as the factory one) and t back the cover.
• Please dispose of this correctly.
• Light bulb is consumption material and is not covered by
the warranty!
• Bulb lamps used in this appliance are special purpose
lamps selected for household appliances use only. They
are not suitable for household room illumination.
Troubleshooting guide