Operation Manual
142396
13
Fault: Cause/Remedy
The appliance does not operate
after connection to the mains:
• Check if there is power in the socket and if the appliance is
switched on.
Cooling system operates
continuously without intermittent
stoppages:
• Ambient temperature too high.
• Frequent opening of the door, (open too long).
• Door not closed properly (particle between door gasket,
sagged door, check gasket sealing, etc...).
• Excessive quantity of fresh food inserted at once.
• Refrigerator sensor (A) is crammed with fresh food. Free
the sensor and allow air to circulate around it.
• Check air circulation for suffi cient cooling of the
compressor, and clean the condenser.
Excessive ice formation at the rear
interior wall of the refrigerator:
• Frequent opening of the door, door open too long.
• Placing hot food in the refrigerator.
• Food is touching the rear interior panel.
• Bad door sealing; clean or replace the gasket if dirty or
damaged.
Water dripping from the appliance: • Drain outlet is clogged, drain water drips past the
collection groove.
• Clean the clogged outlet using plastic straw.
• Please thaw out larger ice deposits manually (see chapter
Defrosting).
Bulb replacement:
• Before replacing the light bulb, disconnect the appliance
form the power supply. Using the screwdriver remove the
cover, replace the bulb with a new one (E 14, max. same
voltage as the factory one) and fi t back the cover.
• Please dispose of this correctly.
• Light bulb is consumption material and is not covered by
the warranty!
• Bulb lamps used in this appliance are special purpose
lamps selected for household appliances use only. They
are not suitable for household room illumination.
Troubleshooting guide