Operation Manual

Instructions for Use
13
Placing and Installation
Choosing the Right Place
Place the appliance in a dry and regularly
ventilated room. Allowed ambient temperature
depends on the model (class) of the
appliance and is stated on the rating plate of
the appliance.
Never place the appliance near heat emitting
devices (e.g. cooker, radiator, water heater or
similar devices) and do not expose it to direct
sunlight.
The appliance should be positioned at least 3
cm away from the electric or gas cooker and
at least 30 cm away from the oil or coal stove.
If this is not possible, use an appropriate
insulation.
Behind the appliance there should be free
space at least 200 cm² wide and above the
appliance the high kitchen units should be at
least 5 cm away from the appliance in order
to assure adequate ventilation of the
condenser unit.
Class Ambient temperature
SN (sub-normal) from + 10°C to + 32°C
N (normal) from + 16°C to + 32°C
ST (sub-tropical) from + 16°C to + 38°C
T (tropical) from + 16°C to + 43°C
Placing the Appliance
xPlace the appliance firmly on a solid base.
Level it with the two adjustable feet, located
on the front.
xThe appliance with ventilation grid may be
placed close to the wall. The grid enables
sufficient air circulation, required for
adequate ventilation of the rear wall.
Connection to Power Supply
Connect the appliance with the cable and
plug to the power supply socket outlet with a
ground terminal (safety socket).
Required nominal voltage and frequency are
indicated on the rating plate.
The connection to the mains supply and
earthing have to be made according to
current standards and regulations. The
appliance resists temporary voltage tolerance
up to -6 to + 6 %.