Operation Manual
Instructions for Use, Building- in and Connecting
10
x The setting elements of the double burner are
accessible behind the protective plate of the
main nozzle.
x Remove the control knobs along with the seal
gaskets.
Gas faucet (fig.2)
Minimum heat input setting screw
Nozzle chart - glas ceramic hob
Gasart
Wobbezahl
Auxiliary burner Normal burner Large burner
max min max min max min
Natural gas H
p=20 mbar
Nominal heat
input (kW)
1 0,32 1,75 0,45 3 0,75
Wo=40,9
y
54,7 MJ/m
3
Consumption (l/h)
95,21 30,47 166,62 42,85 285,64 71,41
Nozzle num.
72
•
97
•
115
•
Nozzle code
690771 690772 690773
Liquid gas, 3B/P
p=30 mbar
Nominal heat
input (kW)
1 0,32 1,75 0,45 3 0,75
Liquid gas 3+ Consumption (g/h)
72,71 23,27 127,24 32,72 218,12 54,53
p
=28-30/37 mbar Nozzle num.
50 29/24 65 33/26 85 43/33
Wo=72,9
y
87,3 MJ/ m
3
Nozzle code
690780 690781 690782
x Built-in regulation knobs are intended for liquefied gas. In case of natural gas (municipal gas line) they
need to be set according to the required gas flow (unscrew for maximum 1,5 turn from the tightened
position).
** Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the gas distribution
company or by the authorized service!
WE RESERVE THE RIGHT TO ALTER THE SPECIFICATIONS WITH NO INFLUENCE
ON THE OPERATION OF THE APPLIANCE.