Please note that if this hob is not located above an oven and
is tted above a cabinet, then a barrier MUST be installed
underneath the hob in order to prevent access to the
underside of the hob.
Cooking hobs can be installed into worktops that are 30 to 50
mm thick.
The kitchen furniture element underneath the hob should not
be tted with a drawer. If the kitchen furniture element as a
horizontal partition wall, it should be installed no less than 60
millimeters from the lower surface of the worktop. The space
between the partition wall and the hob must be empty; no
objects should be placed into that gap. (Partition wall must be
removable from the bottom).
On the furniture back wall there should be a cutout with width of at
least 175 mm along the entire width of the furniture element.
Only type EVP4..,EVP2.., ovens tted with a cooling fan may
be installed underneath this cooking hob.
SVK7
min 20
708-710
min 600488-490
min 40
47
min 50
750-755
R10
510-515
51-55
SVK8
min 20
808-810
min 600488-490
min 40
47
min 50
850-855
R10
510-515
51-55