User Manual

452969
• Cooking hobs can be installed into worktops that are 30
to 50 mm thick.
• If the board is thicker than 40 mm, its inner edge should
be trimmed, or ground (Figure A). Thus, su cient air
circulation will be provided.
• If the thickness of your counter top exceeds 30 mm,
then the opening for the hob should be made in the
middle of the oven, with su cient clearance from the
front edge of the counter top so that the induction hob
does not touch the oven shield.
• If you wish to install the induction hob into an existing
opening, make sure if this is possible given the required
installation dimensions (installation depth of 56 mm).
• Worktop must be placed absolutely horizontal.
• Suitably protect the edges of the cut aperture.
• By means of the supplied screws 4 fasten the supplied
tightening brackets 4 fasten to the front and the rear
side of the cooking hob and to the prepared aperture.
• Connect the cooking hob to the mains power supply
(see instructions for the connection of the cooking hob
to mains power supply).
• Insert the hob into the cut aperture.
• Press the hob fi rmly towards the worktop from above.
• For screwing down the fi xing clip it is not allowed to
use screws longer than 6,5 mm.
Installation procedure
19
- SIVK6
min 20
558-560
min 600488-490
min 40
57
min 50
R10
595-600
510-515
61-65
Worktop cutout