Environmental and electrical reliability tests
Mechanical reliability tests
Version 1.0 (September 2019)
Table 4. Verified results for environmental and electrical reliability tests
Test Conditions Verified
Heat soak Non-op: 60°C/90%RH 72hrs
Temp cycling Non-op: -2C/6C 300 cycles
Short term survivability Non-op: 85°C/20%RH, 18hrs 18 hours
Long-term operational stress (LTOS) Op: 40°C/90%RH 1000 hours
ESD - Air discharge 15~3C, 30~60% RH 12 kV
ESD - Contact discharge 15~3C, 30~60% RH 8 kV
Table 5. Verified results for mechanical reliability tests
Test Conditions Verified
0.5m controlled drop on
wood
6 faces, 12 edges, 3/4" wood 18 drops
0.5m tumble Impact surface: steel plate > 3 mm thick 50 drops
Repetitive drop 75 mm drop on plywood, six faces 50 drops
Vibration 3 axes (X, Y and Z), 15 minutes per axis, 10-500Hz. Amplitude: 2.16
Grms
45 minutes
USB-C connector cycling Manual plug/ unplug 1000 cycles
USB-C connector side load
2.5kg
2.5 kgf load, 15 mm from the plug, 2 orientations 50 cycles
Pressure & squeeze - 50kg 50 kgf, 100 mm rubber pad 10 cycles
Pressure & squeeze - 5kg 5 kgf, 10 mm rubber pad 10 cycles
USB cable 120° bend 60° CW + 60° CCW, 453 gf tension, 42 rpm 100 cycles