SDS
Issue date: 2021/1/4
Reference No: DS-2021/1/4-01!
MATERIAL SAFETY DATA SHEET
Special Fire-
Fighting
Procedures:
In case of fire in cell original containers, use CO2 or dry chemical
extinguisher; For fire in an adjacent area, water can be used.
Section 6. Accidental Release Measures
On Land:
Place material into suitable containers, If the skin has come into contact with the electrolyte, it
should be washed thoroughly with water, Sand or earth should be used to absorb any exuded
material. Seal leaking battery and contaminated absorbent material should be treated by local
regulation, and call local fire/police department to ask for help.
In Water:
If possible, remove from water far from body in special fixture, and call local fire/police
department to ask for help
Section 7. Handling and Storage
Handling
1. Take all precautions mentioned in this document and operate the battery
within the temperature range of -20℃ and 45℃.
2. No special protective clothing required for handling individual cells in
corrective operational method.
3. Improper handling of lithium ion battery may result in injury or damage
from electrolyte leakage, heating, ignition or explosion. So do not crush,
pierce, short cell/battery terminals with conductive material; Do not
directly heat or solder; do not throw into fire; do not place cell/battery in
non conductive trays.
Storage
The lithium ion battery should be between 25% and 75% of full charge
when stored for a long period of time. Stored in a cool, dry, and well
ventilated area. Elevated temperatures can result in loss of battery
performance, leakage, or rust. Do not expose the battery to open flames.
Section 8. Exposure Controls/Personal Protection
Engineering
Controls
keep away from heat and open flame, prevent hard & sharp thing
penetration, store in a cool & dry place.
Ventilation
Not necessary under normal conditions
Respiratory
Protection
Not necessary under conditions of normal use. If battery is burning, leave
the area immediately. During fire fighting fireman should use self-contained
breathing, full-face respiratory equipment. Fires may be fought but only
from safe fire fighting distance, evacuate all persons from the area of fire
immediately.