SDS

06/07/2018Revision:
Page: 4
Goof Off Professional Strength VOC Compliant
SAFETY DATA SHEET
03/05/2018Supersedes Revision:
Flammability Classification:
6. ACCIDENTAL RELEASE MEASURES
Vapors may cause flash fire or ignite explosively.
Clean up: Keep unnecessary people away; isolate hazard area and deny entry. Stay
upwind, out of low areas, and ventilate closed spaces before entering. Shut off ignition
sources; keep flares, smoking or flames out of hazard area. Use non-sparking tools.
Use proper bonding and grounding methods for all equipment and processes. Keep out
of waterways and bodies of water. Be cautious of vapors collecting in small enclosed
spaces, sewers, low lying areas, confined spaces, etc.
Small spills: Take up with sand, earth or other noncombustible absorbent material and
place in a plastic container where applicable.
Large spills: Dike far ahead of spill for later disposal.
Waste Disposal: Dispose in accordance with applicable local, state and federal
regulations.
Steps To Be Taken In Case
Material Is Released Or
Spilled:
7. HANDLING AND STORAGE
Read carefully all cautions and directions on product label before use. Since empty
container retains residue, follow all label warnings even after container is empty.
Dispose of empty container according to all regulations. Do not reuse this container.
Do not use this product near any source of heat or open flame, furnace areas, pilot
lights, stoves, etc.
Do not use in small enclosed spaces, such as basements and bathrooms. Vapors can
accumulate and explode if ignited.
Do not spread this product over large surface areas because fire and health safety risks
will increase dramatically.
Precautions To Be Taken in
Handling:
Keep container tightly closed when not in use. Store in a cool, dry place. Do not store
near flames or at elevated temperatures.
Precautions To Be Taken in
Storing:
Keep away from heat, sparks and open flame. No smoking.
Other Precautions:
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
OSHA TWA ACGIH TWACAS # Partial Chemical Name Other Limits
PEL: 1000 ppm TLV: 500 ppm
STEL: 750 ppm
67-64-1 Acetone {2-Propanone}
No data.
PEL: 100 ppm TLV: 100 ppm
STEL: 150 ppm
1330-20-7 Xylene (mixed isomers) {Benzene,
dimethyl-}
No data.
PEL: 100 ppm TLV: 100 ppm
STEL: 125 ppm
100-41-4 Ethylbenzene {Ethylbenzol;
Phenylethane}
No data.
PEL: 200 ppm TLV: 200 ppm
STEL: 250 ppm
67-56-1 Methanol {Methyl alcohol; Carbinol;
Wood alcohol}
No data.
Licensed to W.M. Barr and Company
GHS format