Installation Instructions
4
22. Turn adjustment screw out (counterclockwise) to decrease
pressure, turn in (clockwise) to increase pressure. Only
small variations in gas flow should be made by means of
the pressure regulator adjustment. In no case should the
final manifold pressure vary more than plus or minus 0.3”
water column from the specified nominal pressure. Any
major changes in flow should be made by changing the
size of the burner orifices. The measured input rate to the
furnace must not exceed the rating specified on the unit
rating plate.
23. Reset all other appliances so they function normally.
24. Turn off gas and electrical supply to the furnace, remove
the manometer hose from the pressure taps, and tighten
the inlet and outlet pressure tap screws using the 3/32”
Allen wrench (clockwise 7 in-lb minimum).
25. If regulator adjustment screw (removed in step 11) is white,
the gasket supplied with the kit must be installed on the
regulator cover screw. The gasket is not required if the
regulator adjustment screw is black.
26. Replace the regulator cover screw on the regulator sleeve.
27. Attach the kit provided WARNING label to the gas valve
where it can be readily seen. Also attach the small round
L.P. label to the top of the regulator cover screw.
28. Turn on the gas and electrical supply, energize the appli-
ance and recheck for leaks.
29. Observe at least 3 ignition cycles to assure quick and
smooth ignition and burner operation.
30. Reinstall the access panels.
Regulator
Cover Screw
Plastic Regulator
Adjustment Screw
Regulator
Spring
Gasket (From
Conversion Kit)
Regulator
Sleeve
36G22 / 36J22 MODEL
Note: Conversion instructions for the Honeywell
VR8215 gas valve begin on the following page.