Installation Instructions

2
IMPORTANT INFORMATION
“This conversion kit shall be installed by a qualified
service agency in accordance with the
manufacturers instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing
property damage, personal injury or loss of life. The
qualified service agency is responsible for the
proper installation of this kit. The installation is not
proper and complete until the operation of the
converted appliance is checked as specified in the
manufacturers instructions supplied with the kit.”
WARNING”
CARBON
MONOXIDE
POISONING
HAZARD
B10259-216
Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions. If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.
This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area. Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.
CO can cause serious illness including permanent brain damage or death.
Special Warning for Installation of Furnaces or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas
CONTENTS
Important Information .......................................................... 2
Conversion Instructions - WR 36G22 / 36J22 Valve ........... 3
Conversion Instructions - HW VR8215 Valve ....................... 5
NOx Screen Removal ......................................................... 6
Non-Condensing Furnaces & Package Gas-Electric........... 6
T
O
AVOID
PERSONAL
INJURY
,
PROPERTY
DAMAGE
OR
DEATH
,
DUE
TO
LEAKING
GAS
,
CONTACT
YOUR
PROPANE
SUPPLIER
ABOUT
INSTALLING
A
GAS
DETECTING
WARNING
DEVICE
. I
RON
OXIDE
(
RUST
)
CAN
REDUCE
THE
LEVEL
OF
ODORANT
IN
PROPANE
GAS
. A
GAS
DETECTING
DEVICE
IS
THE
ONLY
RELIABLE
METHOD
TO
DETECT
A
PROPANE
GAS
LEAK
.
WARNING
BEFORE BEGINNING CONVERSION:
VALVE IDENTIFICATION
Before beginning conversion, the type valve you have must be
identified. Compare the gas valve presently on the equipment
to the drawing below to identify the correct valve you are
working with. Page numbers for the instructions for that valve
are below each drawing.
INLET
Inlet Pressure
Pressure Regulator
Adjustment
(Under Cap Screw)
Gas Valve
On/Off
Selector
Switch
OUTLET
Ta p
Outlet Pressure
Ta p
White-Rodgers 36G22 / 36J22
Instructions for these valves start on page 3.
FLOW DIRECTION
Gas Valve
ON/OFF Selector
Outlet Pressure
Tap 1/8 NPT 3/16
Inlet Pressure Tap
1/8 NPT 3/16 Allen
Regulator Pressure
A
djustment (Under Cap
Screw), Turn Clockwise to
Increase Pressure, Turn
Honeywell VR8215
Instructions for this valve start on page 5.