Installation Instructions

6
WARNING
To avoid The possibiliTy of explosion or fire, never use a
maTch or open flame To TesT for leaks.
22. Turn adjustment screw out (counterclockwise) to
decrease pressure, turn in (clockwise) to increase
pressure. Only small variations in gas ow should be
made by means of the pressure regulator adjustment.
In no case should the nal manifold pressure vary more
than plus or minus 0.3” water column from the specied
nominal pressure. Any major changes in ow should be
made by changing the size of the burner orices. The
measured input rate to the furnace must not exceed the
rating specied on the unit rating plate.
23. Reset all other appliances so they function normally.
24. Turn off the gas and electrical supply to the appliance,
remove the pressure taps at the gas valve, reinstall the
plugs using pipe joint compound or tape.
25. Replace the regulator cover screw on the regulator
sleeve.
26. Attach the kit provided ATTENTION label to the gas
valve where it can be readily seen.
27. Turn on the gas and electrical supply, energize the
appliance and recheck for leaks.
28. Observe at least 3 ignition cycles to assure quick and
smooth ignition and burner operation.
29. Reinstall the access panels.
NOx SCREEN REMOVAL
WARNING
remove all meTal screens from The heaT exchanger Tubes
when using propane gas. failure To do so may cause
properTy damage, personal injury or deaTh and will void
warranTy coverage.
NOTE: To prevent premature heat exchanger failure, follow
the instructions in the NON-CONDENSING FURNACES
AND PACAKGE GAS-ELECTRIC section to remove all
metal screen inserts from the entrance of heat exchanger
tubes during propane conversions. Not all models will have
metal screen inserts.
NON-CONDENSING FURNACES
AND PACKAGE GAS-ELECTRIC
1. Remove the screws securing the burner box to the
partition panel. Separate burner box from unit.
2. Remove the screw(s) securing the NOx screen retention
plate and remove the plate.
3. Remove and discard NOx screens.
4. Reinstall the NOx screen retention plate and burner box.
Typical NOx Screen Removal