Installation Instructions
2
CONTENTS
Important Information ......................................................... 2
Conversion Instructions - WR 36G22 or 36J22 Valves ...... 3
Conversion Instructions - HW VR8215 Valve ..................... 5
NOx Screen Removal ......................................................... 6
Non-Condensing Furnaces & Package Gas-Electric.......... 6
IMPORTANT INFORMATION
WARNING
“This conversion kiT shall be insTalled by a qualified service
agency in accordance wiTh The manufacTurer’s insTrucTions
and all applicable codes and requiremenTs of The auThoriTy
having jurisdicTion. if The informaTion in These insTrucTions is
noT followed exacTly, a fire,
explosion or producTion of carbon monoxide may
resulT causing properTy damage, personal injury or loss
of life. The qualified service agency is responsible for
The proper insTallaTion of This kiT. The insTallaTion is noT
proper and compleTe unTil The operaTion of The converTed
appliance is checked as specified in The manufacTurer’s
insTrucTions supplied wiTh The kiT.”
CARBON MONOXIDE POISONING HAZARD
B10259-216
Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions. If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.
This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area. Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.
CO can cause serious illness including permanent brain damage or death.
Special Warning for Installation of Furnaces or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas
WARNING
To avoid personal injury, properTy damage or deaTh, due
To leaking gas, conTacT your propane supplier abouT
insTalling a gas deTecTing warning device. iron oxide
(rusT) can reduce The level of odoranT in propane gas.
a gas deTecTing device is The only reliable meThod To
deTecT a propane gas leak.
CAUTION
To avoid The risk of properTy damage, personal injury or
fire, shuT off gas supply firsT, Then disconnecT The elec-
Trical supply before proceeding wiTh conversion.
BEFORE BEGINNING CONVERSION:
VALVE IDENTIFICATION
Before beginning conversion, the type valve you have
must be identied. Compare the gas valve presently on the
equipment to the drawing below to identify the correct valve
you are working with. Page numbers for the instructions for
that valve are below each drawing.
White-Rodgers 36G22 and 36J22
Instructions for these valves start on page 3.
Honeywell VR8215
Instructions for this valve start on page 5.