ATTENTION INSTALLING PERSONNEL
As a professional installer, you have an obligation to know
the product better than the customer. This includes all safety
precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with
this Instruction Manual. Pay special attention to all safety
warnings. Often during installation or repair, it is possible to
place yourself in a position which is more hazardous than
when the unit is in operation.
Remember, it is your responsibility to install the product safely
and to know it well enough to be able to instruct a customer
in its safe use.
Safety is a matter of common sense...a matter of thinking
before acting. Most dealers have a list of specic good safety
practices...follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conict between existing practices and the content of
this manual, the precautions listed here take precedence.
IO-817
01/2014
RECOGNIZE THIS SYMBOL
AS A SAFETY PRECAUTION
DESCRIPTION
This natural gas to L.P. gas conversion kit allows the
36G22 [B1282628, 36J22 (0151M00037)] and VR-8215
(0151M00013) series gas valves to be used on L.P. gas
applications. This conversion kit is for use on all single stage
maximum regulation valves.
Required Tools for Kit Installation
2 Pipe wrenches, properly sized to accommodate the
gas piping and connectors
1 7/16” box wrench or socket wrench
1 1/4” nut driver
1 1/4” regular (atblade) screwdriver
1 Manometers to read inlet & outlet pressure of the gas value
(minimum range: 0” - 20” W.C.)
1 3/16” Allen wrench
2 1/8” NPT hose barb
Pipe joint compound or pipe thread tape that is approved for
use with L.P. gas
Gas leak detection solution, like a soap and water solution.
Always wipe the solution from the joints when testing is
complete.
Prior to performing this conversion refer to the National
Fuel Gas Code (ANSI Z223.1) or in Canada, CAN/CGA-
B149.2-M91 to ensure that the installation is in compliance
with those and all local codes.
PLEASE READ AND FOLLOW THESE INSTRUCTIONS
CAREFULLY.
WARNING
To avoid The possibiliTy of explosion or fire, never use a
maTch or open flame To TesT for leaks.
WARNING
To avoid The possibiliTy of explosion or fire, never use a
maTch or open flame To TesT for leaks.
WARNING
The manufacTurer will noT be responsible for any
injury or properTy damage arising from improper service
or service procedures. This l.p. (liquid peTroleum)
conversion kiT musT be insTalled by a qualified service
person oragency in accordance wiTh The manufacTurer’s
insTrucTions and all applicable codes and requiremenTs of
The auThoriTy having jurisdicTion.
failure To follow These insTrucTions expliciTly may cause
a fire, explosion or The producTion of carbon monoxide,
which can cause properTy damage, personal injury or
deaTh.
if you insTall or perform service on This uniT, you assume
responsibiliTy
for any personal injury or properTy damage
which
may resulT. many jurisdicTions require a license To
insTall
or service heaTing and air condiTioning equipmenT.
KIT CONTENTS
Using the following parts list, ensure that all parts included
in this list are present and in an undamaged condition.
Quantity Part Number Description
1 B10259108 Conversion Label
1 B1880007 Spring Kit for White-Rodgers
36G22 & 36J22 valves
1 0163M00078 Spring Kit for Honeywell
VR8215 Value
1 B40899125 1.25mm Burner Orice
1 IO-817 Installation Instructions
1 0151K00000S Pressure Check Kit Value