Propane Conversion Kit Instructions

2
The following tools and supplies are required:
2 – Pipe wrenches, properly sized to accommodate the
gas piping and connectors
1 – 7/16" box wrench or socket wrench
1 - 5/16" nut driver
1 – 3/16" flat blade screwdriver
1 – 1/4" flat blade screwdriver
1 – 3/16" allen wrench
1 – manometer to read inlet and outlet pressure of the
gas valve (Minimum range: 0”-20” W.C.)
Pipe joint compound or pipe thread tape that is approved
for use with L.P. gas
Gas leak detection solution like a soap and water solu-
tion. Always wipe the solution from the joints when test-
ing is completed.
Prior to performing this conversion, refer to the National Fuel
Gas Code (NFPA 54-02) or in Canada, CAN/CSA-B149.2-05
to ensure that the installation is in compliance with those and
all local codes.
IMPORTANT INFORMATION
CONTENTS
Important Information .......................................................... 2
Conversion Instructions - WR 36G54/36J54 Valve ............... 3
Conversion Instructions - HW VR9205Q Valve .................... 5
NOx Screen Removal ......................................................... 7
Non-Condensing Furnaces & Package Gas-Electric........... 7
B10259-216
CO can cause serious illness including permanent brain
damage or death.
Advertencia especial para la instalación de calentadores ó manejadoras
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
B10259-216
El monóxido de carbono puede causar enfermedades severas
como daño cerebral permanente ó muerte.
Las emisiones de moxido de carbono pueden circular a través
del aparato cuando se opera en cualquier modo.
B10259-216
RISQUE D'EMPOISONNEMENT AU
MONOXYDE DE CARBONE
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appareil produisant du monoxyde
de carbone continue de fonctionner au sein de la zone confinée.