Installation Instructions
4
White-Rodgers 36F Valve
White-Rodgers 36E Valve
Left Facing Gas Inlet
Figure 3
White-Rodgers 36G/36J Valve
Right Facing Gas Inlet
(Left Facing Similar)
*If there is interference with the Pressure Switch position,
rotate Pressure Switch 90 degrees.
Figure 4
Honeywell VR82, V 9205Q Valves or
VR9205R (Modulating) Valve
Used on 90%+ Models
R
COUNTERFLOW
Fi
g
ure 5
UPFLOW
80% MODELS USING HONEYWELL VR82,
VR9205Q OR WHITE-RODGERS 36G/36J
GAS VALVES
NOTE: All threaded connections must be sealed with Teflon
tape or pipe dope. Pipe sealant must be approved for use
with propane gas.
1. Install field-supplied 90 degree street elbow into gas valve.
2. Install field-supplied 1/2” x length required to exit wrapper
into 90 degree street elbow for left side gas outlet. Install
field supplied 1/2” x length required to exit wrapper on the
right side of the gas outlet (See Figure 6).
3. Place 1/2” tee on pipe.
4. With gas valve and manifold installed in the unit, connect
the gas supply line into 1/2” tee as required (typically op-
posite of gas valve side).
5. Install 1/2” x 1/8" bushing into 1/2” tee in the remaining
opening.