Specifications
40 www.amana-hac.com SS-AHKR
SS-AHKR www.amana-hac.com PB
Amana® is a trademark of Maytag Corporaon or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our connuing
commitment to quality products may mean a change in specicaons without noce. ©2017 Goodman Company, L.P. • Houston, Texas • Printed in the USA.
Electrical Data for APH13H Packaged Units (Blower Only, Heat Mode)
Model and
Heat Kit Usage
Circuit #1 Circuit #2 Single-Point Kit
Actual kW /
BTU@ 240V
MCA¹ MOP² MCA¹ MOP² MCA¹ MOP²
APH1324H41** 1.9 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 43 50 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 55 60 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 68 70 9.5 / 32,400
APH1330H41** 2.3 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 -- -- 45 50 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 -- -- 57 60 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 -- -- 70 80 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 95 100 14.25 / 48,600
APH1336H41** 2.3 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 49 60 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 61 70 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 74 80 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 98 100 14.25 / 48,600
APH1342H41** 3.6 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 -- -- 51 60 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 -- -- 63 70 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 -- -- 76 80 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 101 110 14.25 / 48,600
HKP-20C* 43 / 49 45 / 50 43 / 49 45 / 50 128 150 19.0 / 64,800
APH1348H41** 3.6 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 54 60 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 66 70 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 79 80 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 103 110 14.25 / 48,600
HKP-20C* 43 / 49 45 / 50 43 / 49 45 / 50 131 150 19.0 / 64,800
APH1360H41** 7.5 --- --- --- -- -- ---
HKR-05*, HKR-05C* 21 / 25 25 / 25 --- --- 65 80 4.75 / 16,200
HKR-08*, HKR-08C* 32 / 36 35 / 40 --- --- 77 90 7 / 23,800
HKR-10*, HKR-10C* 43 / 49 45 / 50 --- --- 90 100 9.5 / 32,400
HKP-15C* 43 / 49 45 / 50 21 / 25 25 / 25 114 125 14.25 / 48,600
HKP-20C* 43 / 49 45 / 50 43 / 49 45 / 50 142 150 19.0 / 64,800
¹ Minimum Circuit Ampacity @ 208 / 240 V
² Maximum Overcurrent Protecon Device @ 208 / 240 V
* Revision level that may or may not be designated
C Circuit breaker opon
^ Heat Kit requires three-phase power supply
Note: HKP-15C* and HKP-20C* replace HKR-15C and HKR-20C respecvely to meet new UL1995 requirements.