GVZC20 Service Manual

SERVICING
76
CTK04 ADDENDUM
DEHUMIDIFICATION SELECT*
When Dehumidication mode exists, the circulating fan out-
put is reduced, increasing system run time, over cooling the
evaporator coil and ultimately removing more humidity from
the structure than if only in cooling mode. The system can
have Dehumidication operation in setting “STD”, “A”, “B” or
“C” of “Dehumidication Select” based on dehumidication
demand. Setting “STD” allows for the widest compressor
operation range with lower CFM than Cooling mode.
In the Enhanced Dehumidication (setting A, B and C)
the indoor airow is lower than Standard Dehumidication
(STD). Setting “A” allows for the same compressor oper-
ation range in Dehumidication operation with lower CFM
than standard dehumidication (STD). Setting “B” limits
compressor operation range and keeps high dehumidica-
tion capacity. In setting “C” the system runs xed at 100%
compressor and airow. See Figure 1.
NOTE: In high humidity environments, sweating on supply
ducts, cased coils or air handler cabinets can become an
issue in Enhanced Dehumidication operation. It is strongly
recommended covering then with 2” berglass insulation for
these installations.
* The specication of *VZC200241AF, 0361AE, 0481AE
and 0601AE or earlier models are di󰀨erent from this
specication.
For details, see the Installation Manual or Service Manual
that matches the Major and Minor revision of model name.
CFM
Min
Compressor speed
Max
C
B
A
CFM control