GVZC20 Service Manual
SERVICING
72
CTK04 ADDENDUM
BOOST MODE
BOOST MODE enables the system to operate at a higher
compressor speed than rated maximum compressor speed
and satisfy the structural load more eectively during higher
ambient outdoor conditions. BOOST MODE is initiated by
an outdoor temperature sensor located in the outdoor unit.
Please note that outdoor equipment operational sound lev-
els may increase while the equipment is running in BOOST
MODE. Disabling BOOST MODE will provide the quietest
and most ecient operation.
NOTE: BOOST MODE is applicable only for *VZC20** or
later revision. BOOST MODE performance is most eective
when paired with an electronic expansion valve enabled
indoor unit.
BOOST MODE is ON by default and is activated when the
outdoor temperature reaches 105°F. BOOST MODE can
be disabled and enabled and the activation temperature
adjusted in the BOOST TEMP menu using the following
procedure:
1. On the CTK04 HOME screen, select MENU.
2. From the MENU screen, select COMFORTNET™ USER
MENU.
HOME FAN
SYSTEM MENU
Tue, Apr 1,2014
1:00 pm
INDOOR
Humidity39 %
72°
OUTDOOR
STATUS
cool mode
69°
SET TO
76°
HOME FAN
SYSTEM
MENU
Security Sengs
Dealer Informaon
Installer Opons
ComfortNet User Menu