GVZC20 Service Manual

CTK04 ADDENDUM
SERVICING
64

Setting
No.
setoN namec i vreS / re l l at sn Ign i t t eSs t ne t noC
1 Maximum Defrost Interval
0: 30min.
1: 60min.
2: 90min.
3: 120min.
esU e r u t uFA/Nt n e r r uC mum i x aM t eS2
3 Vertical Rise
0:Same Level
1:Outdoor Lower
2:Indoor Lower
4 System Verification Test (System Test)
0:ON 1:OFF
7 Force Defrost Cycle
0:ON 1:OFF
8 Pump Down
0:ON 1:OFF
9Charge Mode
0:ON 1:OFF
*gn i l ooC r o f SP R r osse r p moC mu mi xaM01
*gn i t aeH r o f SPR r osse r p moC mu mi xaM11
12
BOOST Mode Selection
0:ON
1:OFF
13
BOOST Mode Temperature
0:105F
, 1:100F, 2:95F, 3:90F,
4:85F, 5:80F, 6:75F, 7:70F,
8:Always ON
*Depends on tonnage. Can adjust compressor RPS in each 0.5 RPS
NOTES:
Parameters as per factory setting are highlighted in bold and underlined.
BOOST MODE is applicable only for *VXC20**1 or later revision.
