GVZC20 Service Manual

SERVICING
54
TROUBLESHOOTING- OUTDOOR UNIT AND INDOOR UNIT FOR EEV APPLICABLE UNIT
Seng Funcon
1 OFF No Use
2 OFF No Use
3 OFF No Use
4 OFF No Use
5 OFF No Use
6 OFF No Use
7 OFF No Use
8 OFF No Use
9 OFF Heater Kit Selecon in Emergency Mode
10 OFF Heater Kit Selecon in Emergency Mode
11 OFF Heater Kit Selecon in Emergency Mode
12 OFF Heater Kit Selecon in Emergency Mode
13 ON
Allow in Emergency Mode (Fan Emergency Mode)
14 OFF Allow in Emergency Mode (Fan Emergency Mode)
15 ON EEV Enable**
16 OFF No Use
17 ON Emergency EEV Opening
18 OFF Emergency EEV Opening
19 OFF EEV Emergency Mode**
20 OFF No Use
21 OFF
Emergency mod
e (Cooling and Hea�ng Emergency Mode)
22 OFF Emergency mod
e (Cooling and Hea�ng Emergency Mode)
23 OFF No Use
24 OFF No Use
1 ON CT Communicaon Enable*
2 ON CT Communicaon Enable*
1 OFF Cooling Emergency mode*
2 OFF Cooling Emergency mode*
ID DS-5
ID DS-6
OD DS-1
OD DS-2
Switch #
Dipswitch
Default Factory Sengs
ID DS-1
ID DS-2
ID DS-3
ID DS-4
* Must be set at factory setting to operate the normal mode.
** Must be set at factory setting indoor unit with EEV. It’s prohibited to change setting.