GSZC18 Installation

18
TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODES
Digit3 Digit2 Digit 1
• Run time for last 4 cycles is less
than 3 minutes each.
• Compressor protector has not tripped.
Low pressure and high pressure
switches are closed.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK
0 3 • Short Cycling • Intermittent
thermostat demand.
• Faulty compressor
relay.
• Check thermostat
and thermostat wiring;
repair/ replace as
needed.
• Check compressor
relay operation;
replace control as
needed.
Turn power OFF prior
to repair.
• Fault will clear after 4
consecutive normal
cycles.
Fault may be cleared
by cycling 24VAC to
control.
Replace with correct
replacement part(s).
• Minimum
compressor run time is
changed from 30
seconds to 3 minutes.
Compressor and outdoor fun are off.
• Compressor protector trips four
consecutive times.
Average run time between trips is
less than 1 5 seconds.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK
0 4 • Locked Rotor • Compressor
bearings are seized.
• Failed compressor
run capacitor.
Faulty run capacitor
wiring.
Low line voltage.
• Check compressor
operation; repair/
replace as needed.
• Check run capacitor;
replace as needed.
Check wiring;
repair/replace as
needed.
Verify line voltage is
within range on rating
plate; contact local
utility is out of range.
Turn power OFF prior
to repair.
• Must clear fault by
cycling 24V AC to
control.
Replace with correct
replacement part(s).
Compressor and outdoor fun are off
for greater than 4 hours.
Low pressure and high pressure
switches are closed.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK
0 5 • Open Circuit • Power is
disconnected.
• Failed compressor
protector.
• Compressor not
properly wired to
control.
• Check circuit break
ers and fuses .
• Check wiring to unit;
repair/ replace as
needed.
• Check compressor
repair/replace as
needed
• Check compressor
wiring; repair/ replace
as
needed.
• Turn power OFF
prior to repair.
• Fault will clear after 1
normal cycle.
Fault may be cleared
by cycling 24V AC to
control.
Replace with correct
replacement part(s).
Compressor and outdoor fun are off.
Low pressure and high pressure
switches are closed.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK
0 6 Open Start Circuit Compressor start
winding is open.
• Failed compressor
run capacitor.
Faulty run capacitor
wiring.
• Compressor not
properly wired to
control.
• Faulty compressor
wiring.
• Check compressor
repair/replace as
needed.
• Check run capacitor;
replace as needed.
Check wiring;
repair/replace as
needed.
Turn power OFF prior
to repair.
• Fault will clear after 1
normal cycle.
Fault may be cleared
by cycling 24V AC to
control.
Replace will correct
replacement part(s).
UNITARY DIAGNOSTIC CODES
Symptoms
of
Abnormal Operation (Legacy
&
ComfortNet™
Thermostat)
Diagnostic/Status
LED Display Codes
Fault Description
Possible
Causes
Corrective Actions
Notes
&
Cautions