Installation Manual

11
HeAt set-up
This menu allows for the adjustment of several heating perfor-
mance variables. Heat Airow Trim (range from -10% to 10%
in 2% increments), Heat Fan ON Delay, Heat Fan OFF Delay,
Defrost Interval and Compressor Delay can be adjusted in this
menu. Defrost Interval determines the amount of compressor
run time between defrost cycles. Compressor delay selects a
compressor off time after a reversing valve shift.
deviCe stAtus
The current system operational mode and requested indoor
CFM is reported in this menu. This information can be used
for troubleshooting purposes.
tHermostAt menu
If this heat pump is installed with a ComfortBridge compatible
furnace, the system is recognized as a dual fuel system. The
balance point temperature should be set via the indoor unit.
See indoor unit instruction manual for details on how to set
the balance point.
system trouBlesHooting
NOTE: Refer to the instructions accompanying the CT
compatible indoor air handler/furnace/modular blower unit for
troubleshooting information regarding indoor unit diagnostics..
Refer to the Troubleshooting Chart at the end of this manual
for a listing of possible air conditioner and heat pump error
codes, possible causes and corrective actions.