GSZC16 Specs
Table Of Contents
18 www.goodmanmfg.com SS-GSZC16
SS-GSZC16 www.goodmanmfg.com 19
59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
80
1540
MBh 57.7 58.5 60.2 62.9 57.2 58.0 59.7 62.3 55.7 56.5 58.2 60.8 53.1 53.9 55.6 58.3 50.0 50.8 52.5 55.1 47.1 47.9 49.6 52.2
S/T 0.85 0.77 0.64
0.49 1.00 0.78 0.64 0.50 1.00
0.80 0.67 0.53 1.00 0.82 0.69 0.55
1.00 0.85 0.71 0.57 1.00 1.00 0.76
0.62
∆T 28 26 23 19 28 26 23 19 28 26 23 19 28 26 23 19 28 26 22 19 29 27 24 20
kW 3.20 3.20 3.19 3.22 3.60 3.60 3.59 3.62 4.05 4.05 4.04 4.08 4.54 4.54 4.53 4.56 5.09 5.08 5.08 5.11 5.73 5.72 5.72 5.75
Amps 12.6 12.6 12.6 12.7 14.5 14.4 14.4 14.6 16.5 16.5 16.5 16.6 18.8 18.7 18.7 18.8 21.2 21.2 21.2 21.3 24.2 24.2 24.1 24.3
Hi PR 248 250 251 256 288 289 290 295 329 330 331 336 373 374 376 380 420 421 423 428 471 472 474 478
Lo PR 117 118 121 126 124 126 129 134 130 132 135 140 136 137 140 145 141 142 145 150 147 149 152 157
1800
MBh 58.6 59.4 61.1 63.7 58.1 58.9 60.6 63.2 56.6 57.4 59.1 61.7 54.0 54.8 56.5 59.1 50.8 51.6 53.3 56.0 47.9 48.7 50.5 53.1
S/T 0.92 0.85 0.71 0.57 1.00 0.85 0.72 0.57 1.00 0.88 0.74 0.60 1.00 0.90 0.76 0.62 1.00 0.92 0.78 0.64 1.00 1.00 0.83 0.69
∆T 27 25 21 18 27 25 21 18 27 25 22 18 27 25 21 18 26 24 21 18 27 26 22 19
kW 3.22 3.22 3.21 3.25 3.63 3.63 3.62 3.65 4.08 4.08 4.07 4.10 4.57 4.56 4.56 4.59 5.11 5.11 5.10 5.13 5.75 5.75 5.74 5.77
Amps 12.7 12.7 12.7 12.8 14.6 14.6 14.5 14.7 16.6 16.6 16.6 16.7 18.9 18.9 18.8 19.0 21.4 21.3 21.3 21.5 24.3 24.3 24.2 24.4
Hi PR 251 252 254 258 290 291 293 297 331 332 334 338 375 376 378 382 423 424 426 430 474 475 476 481
Lo PR 119 120 123 128 126 128 131 135 132 134 137 142 138 139 142 147 143 144 147 152 149 151 154 159
1980
MBh 59.3 60.1 61.8 64.4 58.8 59.6 61.3 63.9 57.3 58.1 59.8 62.4 54.7 55.5 57.2 59.8 51.5 52.3 54.1 56.7 48.6 49.5 51.2 53.8
S/T 0.95 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.91 0.77 0.63 1.00 0.93 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72
∆T 26 24 21 17 26 24 21 17 26 24 21 17 26 24 21 17 26 24 20 17 27 25 21 18
kW 3.24 3.24 3.23 3.26 3.64 3.64 3.63 3.66 4.09 4.09 4.08 4.11 4.58 4.58 4.57 4.60 5.13 5.12 5.12 5.15 5.76 5.76 5.75 5.79
Amps 12.8 12.8 12.7 12.9 14.6 14.6 14.6 14.7 16.7 16.7 16.7 16.8 18.9 18.9 18.9 19.0 21.4 21.4 21.4 21.5 24.3 24.3 24.3 24.4
253 254 255 260 292 293 295 299 333 334 336 340 377 378 380 384 424 426 427 432 475 476 478 482
Lo PR 121 122 125 130 128 129 132 137 134 135 138 143 139 141 144 148 144 146 149 154 151 152 155 160
85
1540
MBh 58.7 59.5 61.2 63.8 58.2 59.0 60.7 63.3 56.7 57.5 59.2 61.8 54.1 54.9 56.6 59.2 50.9 51.7 53.5 56.1 48.0 48.9 50.6 53.2
S/T 1.00 0.87 0.74 0.60 1.00 0.88 0.74 0.60 1.00 0.91 0.77 0.63 1.00 1.00 0.79 0.65 1.00 1.00 0.81 0.67 1.00 1.00 0.86 0.72
∆T 31 30 26 23 31 30 26 23 32 30 26 23 31 30 26 23 31 29 26 22 32 30 27 24
kW 3.21 3.20 3.20 3.23 3.61 3.61 3.60 3.63 4.06 4.06 4.05 4.08 4.55 4.55 4.54 4.57 5.09 5.09 5.08 5.12 5.73 5.73 5.72 5.75
Amps 12.6 12.6 12.6 12.7 14.5 14.5 14.5 14.6 16.6 16.5 16.5 16.7 18.8 18.8 18.7 18.9 21.3 21.3 21.2 21.4 24.2 24.2 24.2 24.3
Hi PR 250 251 252 257 289 290 292 296 330 331 333 337 374 375 377 381 422 423 424 429 472 473 475 480
Lo PR 119 120 123 128 126 127 130 135 132 134 137 141 137 139 142 147 143 144 147 152 149 150 153 158
1800
MBh 59.5 60.3 62.1 64.7 59.0 59.8 61.6 64.2 57.5 58.3 60.1 62.7 54.9 55.8 57.5 60.1 51.8 52.6 54.3 56.9 48.9 49.7 51.4 54.1
S/T 1.00 0.95 0.81 0.67 1.00 0.95 0.82 0.67 1.00 1.00 0.84 0.70 1.00 1.00 0.86 0.72 1.00 1.00 0.88 0.74 1.00 1.00 0.94 0.79
∆T 30 28 25 21 30 28 25 21 30 29 25 22 30 28 25 21 30 28 25 21 31 29 26 22
kW 3.23 3.23 3.22 3.25 3.64 3.63 3.63 3.66 4.09 4.08 4.08 4.11 4.57 4.57 4.56 4.60 5.12 5.12 5.11 5.14 5.76 5.75 5.75 5.78
Amps 12.8 12.7 12.7 12.9 14.6 14.6 14.6 14.7 16.7 16.7 16.6 16.8 18.9 18.9 18.9 19.0 21.4 21.4 21.3 21.5 24.3 24.3 24.3 24.4
Hi PR 252 253 255 259 291 292 294 298 332 333 335 339 376 377 379 384 424 425 427 431 475 476 478 482
Lo PR 121 122 125 130 128 129 132 137 134 136 138 143 139 141 144 149 145 146 149 154 151 152 155 160
1980
MBh 60.2 61.1 62.8 65.4 59.7 60.5 62.3 64.9 58.2 59.0 60.8 63.4 55.7 56.5 58.2 60.8 52.5 53.3 55.0 57.6 49.6 50.4 52.1 54.8
S/T 1.00 0.98 0.84 0.70 1.00 0.98 0.85 0.70 1.00 1.00 0.87 0.73 1.00 1.00 0.89 0.75 1.00 1.00 0.91 0.77 1.00 1.00 0.96 0.82
∆T 29 28 24 21 29 28 24 21 30 28 24 21 29 28 24 21 29 27 24 20 30 28 25 22
kW 3.25 3.24 3.24 3.27 3.65 3.65 3.64 3.67 4.10 4.10 4.09 4.12 4.59 4.59 4.58 4.61 5.13 5.13 5.12 5.15 5.77 5.77 5.76 5.79
Amps 12.8 12.8 12.8 12.9 14.7 14.7 14.6 14.8 16.7 16.7 16.7 16.8 19.0 19.0 18.9 19.1 21.5 21.4 21.4 21.6 24.4 24.4 24.3 24.5
254 255 257 261 293 294 296 300 334 335 337 341 378 379 381 385 426 427 428 433 476 478 479 484
Lo PR 122 124 127 132 129 131 134 139 136 137 140 145 141 142 145 150 146 147 150 155 152 154 157 162
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions kW = Total system power
High and low pressures are measured at the liquid and sucon service valves. Amps = outdoor unit amps (compressor + fan)
Expanded Cooling Data — GSZC160601C* / CA*F4961*6D*+MBVC2000**-1A*+TX — High Stage