GSZ16 Service Manual
169
WIRING DIAGRAMS
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
VSZ130181A[C/D/E/F], VSZ130241B[B/C/D], VSZ130301A[D/E/F/G]
VSZ130361B[B/C/D], VSZ130421A[C/D/E/F/G],VSZ130481A[C/D],
VSZ130601AC
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO IND OOR UNIT L OW VO LTAG E TE RMI NA L BLOCK & I NDOOR THERMOSTAT.
2) STA RT AS SIS T FACTO RY EQUIP PE D WHE N REQUI RE D.
3) USE COPPER CONDUCTOR ONLY.
4) CRA NK CASE HEATER & CRANKCAS E HE ATE R SWITCH ARE FACTORY INSTALLED OPTION
5) 40VA MINIMUM TRANSFORMER IS REQUI RED.
6) COMMON SIDE OF TRANSFORMER MUST BE GROUNDED.
COMP
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
IO
T1
C
M
A
I
N
R
A
U
X
5
S
SR
SA
2
1
RCCF
SC
T2
C
L1
L2
(IF USED)
NOTE 2
CH
C
F
M
A
I
N
A
U
X
IO
CM
0140R0017 1 - B
OR
BL/PK
BL
RD
O
Y
C
R
COLOR CODE
BK --------------- BLACK
BL/PK ---------- BLUE/PINK STRIPE
BR --------------- BROWN
GR---------------- GREEN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- W HITE
YL --------------- YELLOW
YL/PK----------- YELLOW/PINK STRIPE
COMPONENT C ODE
C - -------- ------ CONTA CTOR
CADM -------- COMFORT ALERT D IAGNOSTIC MODULE
CCR ----------- COMPRESSOR CONTACTOR RELAY
CH ------------- CRANKCASE HEATER
CHS ----------- CRANKCASE HEATER SWITCH
CM ------------ OUTDOOR FAN MOTOR
CMR ---------- CONDENSER MOTOR RELAY
COMP -------- COMPRESSOR
CS ------------- COMPRESSOR SOLENOID
DC ------------- DEFROST CONTROL
DFT ----------- DEFROST TH ERMOSTAT
DT ------------- DISCHARGE THERMOSTAT
HPS ----------- HIGH PRESSURE SWITCH
HVDR -------- HIGH VOLTAGE DEFROST RELAY
IO -------------- INTERNAL OVERLOAD
LPS ---------- LOW PRESSURE SWITCH
LVDR --------- LOW VOLTAGE DEFROST RELAY
LVJB --------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACI TOR FOR COMPRESSOR & FAN
RVC ----------- REVERSING VALVE COIL
SA ------------- START ASSIST
SC ------------- S TART CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING CODE
FA CTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIE
LD WIRING
HIGH VOLTAGE
LOW VOLTAGE
LVJB
CONTROL BOX
SC
RD BL
L2
T2
L1
T1
C
BK
BK
BK
RD
RD
BL
RD
RCCF
F
C
HERM
YL
YL
YL
BR
RD
PU
YL
RD
SR
5
2
1
BK
YL
BL
IO
CM
A
UX
MAIN
BR
PU
YL
C
R
S
RD
BK
A
UX
MAIN
COMP
YL/PK
LPS
EQUIPMENT
GROUND
DF1
DF2
CH
LV DR
R
CNT
INDOOR POWER SUPPLY
DFT
C
Y
DC
DFT
WH W2
DC
BL/PK
HPS
O
C
RV C
W2
R
HVDR
YL/PK
BK
RD
BK
PU
BK
BL
BL
PU
CHS
R-DFT
O-RV
C-RV
LPS
PS2
R-PS1
O
W
C
HPS
CCR
}
FIE LD L OW
VO LT AG E
CONNECTIONS
RD
BK
CH
CH S
RD
SA
(IF USED)
NOTE 2
DFT RVC
RD
BK
BL/PK
BK
GR
Y
T1
L1
T2
L2
A
LT E R N AT E
DOUBLE POLE
CON TACTOR
R
DF1
DF2
0
0- RV
C-RV
W
LVD R
HVDR
CCR
CN T
0
DFT
R-DF T
R-P S1
Y
Y
C
R
C
C
PS 2
YL/ PK
YL/PK
RD
RD
BL/PK
WH
OR
BK
BK
SEE NOTE 4
SEE NOTE 5 & 6
SEE NOTE 4
SEE NOTE 3
BK
BK
RD
NOT E 1
IO










