Installation Manual

14
TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODES
Air conditioner/heat pump fails to
operate.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK d 0
Data not yet on
Network
Air conditioner/ heat
pump is wired as part of
a communicating
system and
integrated control
module does
not contain any shared
data.
Verify system type
(communicating or legacy)
Populate shared data
using memory card
Wire system as legacy
system
Turn power OFF prior to repair.
Use memory card for your specific
model.
Insert memory card BEFORE
turning power ON. Memory card
may be removed after data is loaded.
Turn power OFF before removing
memory card.
Error code will be cleared once
data is loaded.
Air conditioner/heat pump fails to
operate.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK d 1
Invalid Data on
Network
Air conditioner/ heat
pump is wired as part of
a communicating
system and integrated
control module contains
invalid shared data or
network data is invalid
for
the integrated control
module.
Verify system type
(communicating or legacy).
Populate correct shared
data using memory card.
Wire system as legacy
system.
Turn power OFF prior to repair.
Use memory card for your specific
model.
Insert memory card BEFORE
turning power ON. Memory card
may be removed after data is loaded.
Turn power OFF before removing
memory card.
Error code will be cleared once
data is loaded.
Air conditioner/heat pump fails to
operate.
Air conditioner/heat pump operating
at reduced performance.
Air conditioner/heat pump operating
at low stage when e peeled to operate at
high stage.
Integrated control module
diagnostic/status LED display shows
the indicated code.
BLANK d 2 • System
Mis-Match
Air conditioner/ heat
pump is wired as part of
a communicating
system and outdoor unit
requires air flow greater
than indoor units
airflow capability.
Shared data is
incompatible with the
system or missing
parameters.
Verify system type
(communicating or legacy).
Verify shared data is
correct for your specific
model repopulate data if
required.
Wire system as legacy
system.
Turn power OFF prior to repair.
Use memory card for your specific
model.
Insert memory card BEFORE
turning power ON. Memory card
may be removed after data is loaded.
Turn power OFF before removing
memory card.
Error code will be cleared once
data is loaded.
Digit2 Digit 1
UNITARY DIAGNOSTIC CODES
Symptoms of
Abnormal Operation
Diagnostic/Status
LED Display Codes
Fault Description Possible Causes Corrective Actions Notes & Cautions
Digit3