Specifications
Table Of Contents
4 www.goodmanmfg.com SS-GSZ14
SS-GSZ14 www.goodmanmfg.com 5
Product Specifications (cont.)
GSZ14
0361K*
GSZ14
0371A*
GSZ14
0421K*
GSZ14
0481K*
GSZ14
0491K*
GSZ14
0601K*
Cooling (BTU/h) 36,000 33,000 42,000 48,000 48,000 60,000
Heang (BTU/h)
36,000 34,000 42,000 48,000 48,000 60,000
Decibels 74 73 75 75 76 76
RLA 15.4 14.1 16.7 18.5 19.9 26.4
LRA 83.9 72.2 109.0 124.0 109.0 134.0
Type Scroll Scroll Scroll Scroll Scroll Scroll
Horsepower 1/6 1/4 1/6 1/4 1/6 1/4
FLA 0.95 1.30 1.1 1.30 1.1 1.30
Refrigerant Line Size¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ⅞" ⅞" 1⅛" 1⅛" 1⅛" 1⅛"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ¾" ⅞" ⅞" ⅞” ⅞" ⅞"
Standard Line Set Length (max. feet) 80 80 80 80 80 80
Long Line Set Length (max. feet) ²
Equivalent Length 250 250 250 250 250 250
Linear Length 200 200 200 200 200 200
Vercal Length (outdoor below indoor) 80 80 80 80 80 80
Vercal Length (outdoor above indoor) 80 200 80 80 80 80
Valve Connecon Type Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 115 175 153 157 192 205
Volts/Phase (60 Hz)
208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1
Minimum Circuit Ampacity ³
20.2 18.9 22.0 24.4 26.0 34.3
Max. Overcurrent Protecon ⁴
35 30 35 40 45 60
Min / Max Volts
197 / 253 197/253 197 / 253 197 / 253 197 / 253 197 / 253
Electrical Conduit Size
½" or ¾" 1/2" or 3/4" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Equipment Weight (lbs.)
173 220 191 226 273 277
Ship Weight (lbs)
184 240 207 237 288 292
NO NO NO
Proper sizing and installaon of equipment is crical to achieving opmal performance. Split system air condioners and heat pumps must
be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
The www.energystar.gov website provides up-to-date system combinaons cered to meet ENERGY STAR requirements. See Page 24 for all ENERGY STAR cered combinaons
as of this document’s revision date.
¹ Tested and rated in accordance with ARI Standard 210/240
² Reference TP-107* for addional applicaon requirements
³ Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes
⁴ Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
• Installaon of these units requires the specied TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT
THE INDOOR COIL.