Specifications

2 www.goodmanmfg.com SS-GSZ14
SS-GSZ14 www.goodmanmfg.com 3
Product Specifications
GSZ14
0181K*
GSZ14
0191A*
GSZ14
0241K*
GSZ14
0251A*
GSZ14
0301K*
GSZ14
0311A*

Cooling (BTU/h) 18,000 17,400 24,000 23,200 30,000 28,000
Heang (BTU/h)
18,000 18,000 24,000 23,200 30,000 31,000
Decibels 72 72 72 72 74 75

RLA 9.0 9.0 10.9 10.9 13.5 13.5
LRA 47.5 47.5 62.9 62.9 72.5 72.5
Type Scroll Scroll Scroll Scroll Scroll Scroll

Horsepower 1/6 1/6 1/6 1/6 1/6 1/6
FLA 0.95 1.1 0.95 1.1 0.95 1.10

Refrigerant Line Size¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ¾"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ¾”
Standard Line Set Length (max. feet) 80 80 80 80 80 80
Long Line Set Length (max. feet) ²
Equivalent Length 250 250 250 250 250 250
Linear Length 200 200 200 200 200 200
Vercal Length (outdoor below indoor) 80 80 80 80 80 80
Vercal Length (outdoor above indoor) 80 200 80 200 80 200
Valve Connecon Type Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge (oz.) 108 108 108 108 108 160

Volts/Phase (60 Hz)
208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1
Minimum Circuit Ampacity ³
12.2 12.4 14.6 14.7 17.8 17.9
Max. Overcurrent Protecon ⁴
20 20 25 25 30 30
Min / Max Volts
197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197/253
Electrical Conduit Size
½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" 1/2" or 3/4"

Equipment Weight (lbs.)
143 143 143 143 171 186
Ship Weight (lbs)
154 154 154 154 182 206

NO NO NO
 
Proper sizing and installaon of equipment is crical to achieving opmal performance. Split system air condioners and heat pumps must
be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
The www.energystar.gov website provides up-to-date system combinaons cered to meet ENERGY STAR requirements. See Page 24 for all ENERGY STAR cered combinaons
as of this document’s revision date.
¹ Tested and rated in accordance with ARI Standard 210/240
² Reference TP-107* for addional applicaon requirements
³ Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes
Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.

Always check the S&R plate for electrical data on the unit being installed.
Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
Installaon of these units may require the specied TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT
NOT THE INDOOR COIL.