Specifications

26 www.goodmanmfg.com SS-GSXC18
SS-GSXC18 www.goodmanmfg.com 27
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
Wiring Diagram
WIRING CODE FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
HIGH VOLTAGE
FIELD
OPTIONAL HIGH
VOLTAGE
OPTIONAL LOW
VOLTAGE
CO
LOR COD
E
BK --------------- BLACK
BL --------------- BLUE
BL/PK --------- - BLUE/PINK STRIPE
BR -------------- - BROWN
OR --------------- ORANGE
PU -------------- - PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL/PK --------- - YELLOW/PINK STRIPE
1
3
4
6
E11
E16
GR/YL
BL
BR
RELAY
RELAY
RELAY
HERM
COM
START
RUN
230 VAC
SUPPLY
L1
L2
E13
L2 OUT
L2
L1
E10
R
C
START
E5
E8
CAP COM
CH
E21
E17
START
RLY
WH
UC BOARD
LPS
HPS
FUSE
O
L
R
C
W1
Y1
E2
Y2
FAN
RUN
RELAY
RELAY
1
2
1
2
R
C
E25
E29
E28
E26
E24
E23
E22
E14
HIGH
LPCO
HPCO
E47
E1
OAT OCT
OAS
RD
WH
BL
BL
WH
YL
YL
BR
GND
LOW VOLTAGE
BARRIER
BL/PK
BK
YL/PK
YL/PK
RD
BK
BK
BK
BL/PK
RCCF
C
R
S
AUX
MAIN
COMP
CS
Y 2
C
BK
YL
RD
CONTROL BOX
L
Y2
Y1
C
O
L (OPTIONAL)
Y2
Y1
W1
C
LEGACY INDOOR T-STAT
C
R
2
1
C
R
2
1
R
R
C
R
INDOOR POWER SUPPLY 24 VAC
COMMUNICATING INDOOR T-STAT
INDOOR POWER SUPPLY 24 VAC
TO INDOOR COMMUNICATING PCB
0140R00142-G
THIS WIRING SCHEMATIC SHOWS THE LEGACY WIRING FROM
THE FACTORY. THE WIRES GO TO INDOOR T-STAT AS SHOWN
IN "LEGACY INDOOR T-STAT". TO WIRE THE SYSTEM IN
COMMUNICATING MODE, THE INSTALLER HAS TO WORK
THE WIRING AS SHOWN IN "COMMUNICATING INDOOR T-STAT".
REFER TO THE IO MANUAL LOCATED IN COMMUNICATING
T-STAT KIT FOR MORE DETAILS.
FROM
OUTDOOR
UNIT
FROM
OUTDOOR
UNIT
GND
L1
L2
BK
YL
YL
CM
RES
2 5
1
SR SC
OPTIONAL HARD START
COM
PONENT CODE
C --------------- CONTACTOR
CM ------------ CON DENSER FAN MOTOR
COMP ------- - COMPRESSOR
CS ------------ - COMPRESSOR SOLENOID
DT ------------- DISCHARGE THERMOSTAT
HPS ---------- - HIGH PRESSURE SWITCH
IO ------------- - INTERNAL OVERLOAD
LPS ---------- LOW PRESSURE SWITCH
OAS ----------- OUTDOOR AIR SENSOR
RCCF -------- - RUN C APACITOR FOR COMPRESSOR & FAN
SC ------------ - START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------ - START RELAY FOR COMPRESSOR (OPTIONAL)
CH ------------ CRANKCASE HEATE
R (OPTIONAL)
CHS ---------- CRANKCASE HEATER SWITCH (OPTIONA L)
CONTROLS SHOW N WITH THERMOSTAT IN 'OFF' POSITION.
YL
PU
BL
RD
DT
SEE NOTE 1
NOTES:
1. IF DT IS NOT PRESENT, HPS BL/PK WIRE
GOES DIRECTLY TO TERMINAL E29.
2. USE COPPER SUPPLY W IRES ONLY.
3. USE 40VA TRANSFORMER MINIMUM.
4. CRANKCASE HEATER FACTORY
INSTALLED OPTION.
5. USE N.E.C. CLASS 2 WIRES.
H
F
C
BK
L1
L2
K2
C
R
S
COM P
R
S
1
2
5
SC
C
UC C ON TR OL
HERM
CAP
COM
SR
OP TIONA L HA RD
ST ART
EC M FA N
MOT O R
C
HERM
C
RUN
CAP ACITO R
FAN
HIGH V OL TA GE AR EA
LOW VOL TA G E AR EA
O
L
R
C
W 1
Y1
E2
Y2
1
2
LPS
E22
E23
E24
E26
E47
E1
HPS
OA S
DT
E28
E29
E14
CS
1 3
4 6
E11
CM
SEE NOTE 2
NOTE 2
K6
CHS
CH
NOTE 4
CHS
GR/YL
BK
NOTE 4
RD
RD
BK
PU
SEE NOTE 5
SEE NOTE 5
SEE NOTE 5
SEE NOTE 5