Specifications

Product SPecificationS
6 www.goodmanmfg.com SS-GMVM97
SS-GMVM97 www.goodmanmfg.com 7
GMVM971005CNA


GMVM971005CNA


 

CFM

CFM
 

CFM


A
 738 508
A
 1,636 55
Normal 820 564 Normal 1,818 49
 902 620  2,000 45
B
 1,020 706
B
 1,683 53
Normal 1,133 784 Normal 1,870 48
 1,246 862  2,057 44
C
 1,318 884
C
 1,719 52
Normal 1,464 982 Normal 1,910 47
 1,610 1,080  2,101 43
D
 1,562 1,133
D
 1,761 51
Normal 1,736 1,259 Normal 1,957 46
 1,910 1,385  2,153 42
GMVM971205DNA


GMVM971205DNA


 

CFM

CFM
 

CFM


A
 780 492
A
 1,702 63
Normal 867 547 Normal 1,891 57
 954 602  2,080 52
B
 1,044 748
B
 1,746 62
Normal 1,160 831 Normal 1,940 56
 1,276 914  2,134 51
C
 1,320 918
C
 1,771 61
Normal 1,467 1,020 Normal 1,968 55
 1,614 1,122  2,165 50
D
 1,719 1,150
D
 1,825 59
Normal 1,910 1,278 Normal 2,028 53
 2,101 1,406  2,231 48
GMVM97 airFlow data (Cont.)

All furnaces ship as high speed for cooling. Installer must adjust blower
speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.