Specifications

Product SPecificationS
2 www.goodmanmfg.com SS-GMVM97
SS-GMVM97 www.goodmanmfg.com 3
SpeCiFiCationS
GMVM97
0603BNA
GMVM97
0803BNA
GMVM97
0804CNA
GMVM97
1005CNA
GMVM97
1205DNA
GCVM97
0603BNA
GCVM97
0803BNA
GCVM97
0804CNA
GCVM97
1005CNA

High Fire Input¹ 60,000 80,000 80,000 100,000 120,000 60,000 80,000 80,000 100,000
High Fire Output¹ 58,200 77,600 77,600 97,000 116,400 58,200 77,600 77,600 97,000
Low-Fire Steady-State Input¹ 30,000 40,000 40,000 50,000 60,000 30,000 40,000 40,000 50,000
Low-Fire Steady-State Output¹ 29,100 38,800 38,800 48,500 58,200 29,100 38,800 38,800 48,500
AFUE² 98 97 98 97 97 97 97 97 97
Temperature Rise Range (°F) 25 - 55 30 - 60 25 - 55 35 - 65 35 - 65 35 - 65 35 - 65 35 - 65 35 - 65
Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"
No. of Burners 3 4 4 5 6 3 4 4 5

Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5 2 - 5 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5
Size (D x W) 11" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11" 11" x 8" 11" x 8" 11" x 10" 11" x 10"
Horsepower @ 1075 RPM
½ ½ ¾
1 1
½ ½ ¾
1
Speed VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM

Permanent 739 766 862 862 1,035 517 690 690 862
Disposable 370 383 431 431 517 259 345 345 431

 8.8 8.8 11.6 15.4 15.4 8.8 8.8 11.6 15.4
 15 15 15 20 20 15 15 15 20
 118 121 142 144 157 117 122 144 146
¹ Natural Gas BTU/h
 
 
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run

and must be 2" or 3" diameter PVC.
 

 


All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.




and noise issues.


over clearances from the enclosure where accessibility clearances are greater.