Specifications

26 www.goodmanmfg.com SS-GSXC18
SS-GSXC18 www.goodmanmfg.com 27




 
 
  SEER² EER³
GSXC18
0601B*
(Contd.)
CAPT4961*4A* G*VM971205DNA* 55,000 39,600 16.0 12.5 1,600 10510240
CHPF4860D6D*+EEP+TXV 56,000 40,200 15.0 12.0 1,500 10510214
CHPF4860D6D*+MBVC2000**-1A*+TXV 57,000 41,000 16.5 12.5 1,720 10510218
CHPF4860D6D*+TXV G*VC961005CNA* 55,000 39,600 16.0 12.5 1,550 10510221
CHPF4860D6D*+TXV G*VC961005DNA* 54,500 39,200 16.0 12.5 1,610 10510225
CHPF4860D6D*+TXV G*VC961205DNA* 55,000 39,600 16.0 12.5 1,600 10510229
CHPF4860D6D*+TXV G*VC81005C*B* 56,500 40,600 16.0 11.8 1,600 10510233
CHPF4860D6D*+TXV G*VM971005CNA* 55,000 39,600 16.0 12.5 1,550 10510237
CHPF4860D6D*+TXV G*VM971205DNA* 55,000 39,600 16.0 12.5 1,600 10510241
CSCF4860N6D*+EEP+TXV 55,000 40,000 15.0 12.0 1,500 10510215
CSCF4860N6D*+TXV G*VC961005CNA* 55,000 39,600 16.0 12.5 1,550 10510222
CSCF4860N6D*+TXV G*VC961005DNA* 54,500 39,200 16.0 12.5 1,610 10510226
CSCF4860N6D*+TXV G*VC961205DNA* 55,000 39,600 16.0 12.5 1,600 10510230
CSCF4860N6D*+TXV G*VC81005C*B* 56,000 40,400 16.0 11.8 1,600 10510234
CSCF4860N6D*+TXV G*VM971005CNA* 55,000 39,600 16.0 12.5 1,550 10510238
CSCF4860N6D*+TXV G*VM971205DNA* 55,000 39,600 16.0 12.5 1,600 10510242
AHRI Ratings
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F

Always check the S&R plate for electrical data on the unit being installed.
When matching the outdoor unit to the indoor unit, use the piston supplied with the out-
door unit or that specied on the piston kit chart supplied with the indoor unit.
EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S.
The Goodman brand gas furnace contains the EEP cooling me delay.