Specifications

Product Specifications
2 www.goodmanmfg.com SS-DSXC16
SS-DSXC16 www.goodmanmfg.com 3
DSXC16
0241AA/B
DSXC16
0241AC
DSXC16

DSXC16
0361AA/B
DSXC16
0361AC
DSXC16
0481B*
DSXC16
0601B*

Nominal Cooling (BTU/h) 24,000 24,000 24,000 36,000 36,000 48,000 60,000
Decibels 71 71 71 70.4/70.9 70.4/70.9 74 75

RLA 10.3 11.7 11.7 16.7 15.3 21.2 28.8
LRA 52.0 58.0 58.3 82.0 83.0 104.0 152.9

Horsepower (RPM) 1/6 1/6 1/6 1/6 1/6 1/6 1/6
FLA 1.1 1.1 1.1 0.9 0.9 1.2 1.0

Refrigerant Line Size¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ¾" ¾" ⅞" ⅞" 1⅛" 1⅛"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ⅞" ⅞"
Valve Connecon Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 97 97 62 107 107 124 197

Voltage-Hz 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60
Minimum Circuit Ampacity ² 14.0 15.7 15.7 21.8 20.0 27.7 37.2
Max. Overcurrent Protecon ³ 20 20 25 35 35 45 60
Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Power Supply ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
 181 181 181 184 184 219 279
 198 198 198 202 202 241 301
ENERGY STAR®
NO

Proper sizing and installaon of equipment is crical to achieving opmal performance. Split system air condioners and heat pumps must
be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
The www.energystar.gov website provides up-to-date system combinaons cered to meet ENERGY STAR requirements.
See Pages 24-25 for all ENERGY STAR cered combinaons as of this document’s revision date.
¹ Tested and rated in accordance with AHRI Standard 210/240
² Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.

Always check the S&R plate for electrical data on the unit being installed.
Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
Installaon of these units requires the specied TXV Kit to be installed on the indoor coil. THE SPECI-
FIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL.