Specifications
Table Of Contents
AHRI Ratings (cont.)
20 www.goodmanmfg.com SS-DSXC16
SS-DSXC16 www.goodmanmfg.com 21
Energy Star-Certified Combinations ^
Outdoor
Unit
Total¹ SEER² EER³
DSXC16
0241A*
CA*F3636*6D*+MBVC1200**-1A*+TXV 24,000 17,600 16.0 13.0 820 4392752
DSXC16
0361A*
CA*F3743*6D*+MBVC1600**-1A*+TXV 35,000 25,200 16.0 12.5 1,100 4415027
DSXC16
0481B*
CA*F4860*6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.0 12.5 1,600 4559576
^ Proper sizing and installaon of equipment is crical to achieving opmal performance. Split system air condioners and heat pumps
must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energys-
tar.gov. The www.energystar.gov website provides up to date system combinaons cered to meet ENERGY STAR requirements.
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F
• Always check the S&R plate for electrical data on the unit being installed.
• When matching the outdoor unit to the indoor unit, use the piston supplied with the out-
door unit or that specied on the piston kit chart supplied with the indoor unit.
• EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S.
The Goodman Gas Furnace contains the EEP cooling me delay